NAPOLI PIZZA OVENS CARE & USE/INSTALLATION
GAS CONNECTIONS 
...continued 
LP Connections
Make sure the LP cylinder valve is fully closed. It is possible 
for the valve to be open without releasing gas but, as soon 
as you start connecting the regulator, gas will leak from the 
connection.  
Insert the regulator inlet into the cylinder valve and turn the 
black coupler clockwise until the coupler is hand tight. Do 
not over-tighten this connection. 
To disconnect the coupler, first make sure the main cylinder 
valve is turned off. Grasp the coupler and turn counter 
clockwise. The inlet will then disengage. 
Always leak-test the connection after refilling or exchanging 
LP cylinders. (See INDEX: “Leak Test” for further details.)
GAS LINE PURGING
You should purge the gas line of air before attempting to 
light the oven.
•  Make sure all oven controls are in the “OFF” position. 
•  Slowly turn on the main gas supply.
•  Turn on the gas valve and confirm that the igniter is 
glowing. It is furthest from the fuel source and will 
completely purge the lines. It will take several seconds for 
the burner to light. 
•  The igniter will stay ON and light the burner when the air 
has been removed from the line.
•  Wait at least 5 minutes after shutting off the control 
before attempting to light the burners.
GAS CONVERSION KITS
Gas conversion kits are available from Lynx Grills to allow 
the oven to operate on either Natural gas or LPG. These 
kits should be installed by a qualified technician.
The kits come with complete installation instructions. 
These instructions should be read completely and fully 
understood before installing the conversion kit.