Hitachi HUS103030FL3600 User Manual

Page of 43
 
Drawing No. Sheet No.  Revision  6
K6610091
40/43 2005/2/23
 
 
12.2.2    Disable Auto Start 
WIDE LVD 
 
No.
Option Jumper Connector (C3)
Meaning
Remove the Jumper Socket
for C3-9,10 (Default)
1
Install the Jumper Socket
for C3-9,10
2
Spindle motor starts only
by SCSI command
Spindle motor automatically 
starts when the power is 
applied  or in sequence via  ID 
number x 10 seconds from the 
time power is applied if 
C3-13,14 is jumpered.
9
10
23
24
9
10
23
24
 
 
 
12.2.3    Force Single-Ended bus mode 
WIDE LVD 
 
No.
Option Jumper Connector (C3)
Meaning
Remove the Jumper Socket
for C3-11,12 (Default)
1
Install the Jumper Socket
for C3-11,12
2
The drive can be used as 
single-ended or low voltage 
differential mode.
The drive is forced to operate 
only in single-ended mode.
11 23 
12 24 
12  
24 
11 23