Hitachi HUS103030FL3600 User Manual

Page of 43
 
Drawing No. Sheet No.  Revision  6
K6610091
41/43 2005/2/23
 
 
12.2.4  Enable Delayed Start 
WIDE LVD 
 
No.
Option Jumper Connector (C3)
Meaning
Remove the Jumper Socket
for C3-13,14 (Default)
1
Install the Jumper Socket
for C3-13,14
2
Spindle motor automatically 
starts when the power is on.
Spindle motor starts in 
sequence via ID number x 10 
seconds from the time power is 
applied  
(NOTE 1)
13
23
14
24
13
14
23
24
 
Note 1. This time is as follows: 
ID number 0 
to
 7 : ID number x 10sec 
ID number 8 
to
 15 : (ID number - 8) x 10sec 
Note 2. This jumper is valid only when Auto Start setting is done. 
Note 3. If setting for Delayed Start is done by host via SCSI bus connector (C1) in 
SCA-2 LVD drive, remove jumper in C3-13,14. 
Note 4. If DELAY START in SCSI bus connector (C1) in SCA-2 LVD drive is   
       grounded by host, jumper setting in C3-13,14 is invalid.