TOOL PROTECTION & CARE
•  Make sure all couplers are wiped clean before con-
nection.
•  The hydraulic circuit control valve must be in the 
OFF position when coupling or uncoupling hydrau-
lic tools. Failure to do so may result in damage to 
the quick couplers and cause overheating of the hy-
draulic system.
•  Always store the tool in a clean dry space, safe from 
damage or pilferage.
•  Make sure the circuit PRESSURE hose (with male 
quick disconnect) is connected to the 
IN port. The 
circuit RETURN hose (with female quick disconnect) 
is connected to the opposite port. Do not reverse cir-
cuit flow. This can cause damage to internal seals.
•  Always replace hoses, couplings and other parts 
with replacement parts recommended by Stanley 
Hydraulic Tools. Supply hoses must have a mini-
mum working pressure rating of 2500 psi/172 bar.
•  Do not exceed the rated flow (see Specifications) in 
this manual for correct flow rate and model number. 
Rapid failure of the internal seals may result.
•  Always keep critical tool markings, such as warning 
stickers and tags legible.
•  Tool repair should be performed by experienced 
personnel only.
•  Make certain that the recommended relief valves 
are installed in the pressure side of the system.
•  Do not use the tool for applications for which it was 
not intended.
NOTICE
In addition to the Safety Precautions found in 
this manual, observe the following for equipment 
protection and care.