Stanley Black & Decker TA54 User Manual

Page of 18
 TA54 User Manual ◄ 9
HTMA / EHTMA REQUIREMENTS
   Flow Range
   Nominal Operating Pressure
   (at the power supply outlet)
   System relief valve setting
   (at the power supply outlet)
   Maximum back pressure
   (at tool end of the return hose)
   Measured at a max. fluid viscosity of:
   (at min. operating temperature)
   Temperature: Sufficient heat rejection 
    capacity to limit max. fluid temperature to:
   (at max. expected ambient temperature)
   Min. cooling capacity at a temperature 
   difference of between ambient and fluid 
    temps
   
NOTE:
   Do not operate the tool at oil temperatures above 140° F (60° C). Operation at higher temperatures can cause operator
   discomfort at the tool.
   
   Filter
   Min. full-flow filtration
   Sized for flow of at least:
   (For cold temp. startup and max. 
   dirt-holding capacity)
   Hydraulic fluid Petroleum based 
   (premium grade, anti-wear, non-conductive)
   Viscosity (at min. and max. operating temps)
   
NOTE: 
   When choosing hydraulic fluid, the expected oil temperature extremes that will be experienced in service determine the
   most suitable temperature viscosity characteristics. Hydraulic fluids with a viscosity index over 140 will meet the requirements 
   over a wide range of operating temperatures.
   *SSU = Saybolt Seconds Universal
  4-6 gpm   
7-9 gpm   
9-10.5 gpm 
 11-13 gpm
  (15-23 lpm) 
(26-34 lpm) 
(34-40 lpm) 
(42-49 lpm)
  1500 psi  
1500 psi  
1500 psi  
1500 psi
  (103 bar) 
(103 bar) 
(103 bar) 
(103 bar)
 
  
2100-2250 psi 
2100-2250 psi    2200-2300 psi   2100-2250 psi
  (145-155 bar) 
(145-155 bar) 
(152-159 bar) 
(145-155 bar)
  250 psi  
250 psi  
250 psi  
250 psi
  (17 bar)  
(17 bar)  
(17 bar)  
(17 bar)
  400 ssu*  
400 ssu*  
400 ssu*  
400 ssu*
  (82 centistokes)  (82 centistokes)  (82 centistokes)  (82 centistokes)
  140° F   
140° F   
140° F   
140° F 
  (60° C)  
(60° C)  
(60° C)  
(60° C)
  3 hp  
5 hp   
6 hp   
7 hp 
  (2.24 kW) 
(3.73 kW) 
(5.22 kW) 
(4.47 kW)
  40° F   
40° F   
40° F  
40° F
  (22° C)  
(22° C)  
(22° C)  
(22° C)
  25 microns 
25 microns 
25 microns 
25 microns
  30 gpm  
30 gpm  
30 gpm  
30 gpm
  (114 lpm) 
(114 lpm) 
(114 lpm) 
(114 lpm)
  100-400 ssu* 
100-400 ssu* 
100-400 ssu* 
100-400 ssu*
 
             
         (20-82 centistokes)
HTMA 
HYDRAULIC SYSTEM REQUIREMENTS
NOTE: These are general hydraulic system requirements. See tool specification page for tool specific requirements
TOOL TYPE
HTMA / EHTMA REQUIREMENTS
TYPE I
TYPE II
TYPE III
TYPE RR
B
C
D
3.5-4.3 gpm  
4.7-5.8 gpm  
7.1-8.7 gpm  
9.5-11.6 gpm 
 11.8-14.5 gpm
(13.5-16.5 lpm)  (18-22 lpm) 
(27-33 lpm) 
(36-44 lpm) 
(45-55 lpm)
1870 psi  
1500 psi  
1500 psi  
1500 psi  
1500 psi
(129 bar) 
(103 bar) 
(103 bar) 
(103 bar) 
(103 bar)
EHTMA 
HYDRAULIC SYSTEM 
REQUIREMENTS
CLASSIFICATION
   Flow Range
   Nominal Operating Pressure
   (at the power supply outlet)
   
   System relief valve setting
   (at the power supply outlet)
2495 psi  
2000 psi  
2000 psi   
2000 psi  
2000 psi
(172 bar) 
(138 bar) 
(138 bar) 
(138 bar) 
(138 bar)