Stanley Black & Decker TA54 User Manual

Page of 18
8 ► TA54 User Manual
HOSE RECOMMENDATIONS
Oil Flow
Hose Lengths
Inside Diameter
USE
(
Press/Return)
Min. W
orking Pressure
GPM
LPM
FEET
METERS
INCH
MM
PSI
BAR
Certified Non-Conductive Hose - Fiber Braid - for Utility Bucket T
rucks
4-9
15-34
up to 10
up to 3
3/8
10
Both
2250
155
Conductive Hose - W
ire Braid or Fiber Braid -DO NOT USE NEAR ELECTRICAL
 CONDUCT
ORS
4-6
15-23
up to 25
up to 7.5
3/8
10
Both
2500
175
4-6
15-23
26-100
7.5-30
1/2
13
Both
2500
175
5-10.5
19-40
up to 50
up to 15
1/2
13
Both
2500
175
5-10.5
19-40
51-100
15-30
5/8
16
Both
2500
175
5-10.5
19-40
100-300
30-90
5/8
16
Pressure
2500
175
3/4
19
Return
2500
175
10-13
38-49
up to 50
up to 15
5/8
16
Both
2500
175
10-13
38-49
51-100
15-30
5/8
16
Pressure
2500
175
3/4
19
Return
2500
175
10-13
38-49
100-200
30-60
3/4
19
Pressure
2500
175
1
25.4
Return
2500
175
13-16
49-60
up to 25
up to 8
5/8
16
Pressure
2500
175
3/4
19
Return
2500
175
13-16
49-60
26-100
8-30
3/4
19
Pressure
2500
175
1
25.4
Return
2500
175
Figure 1. 
Typical Hose Connections
Tool to Hydraulic Circuit Hose  Recommendations
The chart to the right shows recommended  minimum hose diameters for various hose  lengths based on gallons 
per minute (gpm)/
liters per minute (lpm). 
These recommenda
-
tions are intended 
to keep return line pressure 
(back pressure) to a minimum
 acceptable 
lev
-
el to ensure maximum tool performance. 
This chart 
is intended to 
be used for 
hydraulic 
tool 
applications 
only 
based 
on 
Stanley 
Hy
-
draulic 
Tools tool operating 
requirements and 
should 
not be 
used 
for any 
other 
applications.
All hydraulic 
hose must have at least a rated 
minimum 
working 
pressure 
equal to the maxi
-
mum hydraulic system relief valve setting. 
All hydraulic hose must meet or exceed  specifications as set forth by SAE J517.
PRESSURE
RETURN
<<< FLOW
FLOW >>>