2.1
 
Electrical connection 
 
Make sure that the power line voltage matches the specifications indicated on the rating plate 
located inside the storage compartment.  
This rating plate must never be removed. 
 
 
If the appliance is connected to the supply by means of a fixed connection, install a multipolar 
cut-out device on the line, with contact opening distance equal to or greater than 3 mm
located near the appliance and in an easily reachable position. 
 
 
Connection to the supply may be fixed or with plug and socket. In the latter case the plug and 
socket must be suitable for the cable employed and conform with the regulations in force. 
Regardless of the type of connection, earthing of the appliance is absolutely obligatory. Before 
connection make sure that the supply line is suitably earthed. Avoid the use of reducers, 
adapters or shunts. 
 
 
 
 
 
1 - For operation on 220-240V
: use a three-pole H05RR-F or 
H05V2V2-F cable having a cross section of 3 x 2.5 mm
2
(90 cm 
wide models) or  3 x 1.5 mm
2
 (60 cm wide models). 
 
 
 
 
2 - For operation on 380-415V2N
(only for 90 cm wide 
models): use a four-pole H05RR-F or H05V2V2-F cable having 
a cross section of 4 x 1.5 mm
2
 
 
 
3 - For operation on 380-415V3N
(only for 90 cm wide 
models): use a five-pole H05RR-F or H05V2V2-F cable having
a cross section of 5 x 1.5 mm
2
 
The cable end to be connected to the appliance must be 
provided with ground wire (yellow-green) at least 20 mm longer.
 
 
Caution: only 90 cm wide models can be connected on a two-phase or three-phase 
system.
 
 
2.2
 
Ventilation requirements 
 
The room containing the appliance should have an air supply in accordance with B.S. 5440 
part 2 1989. 
1.
 
All rooms require an opening window or equivalent, and some rooms will require a 
permanent vent as well. 
2.
 
For room volumes up to 5 m
3
 an air vent of 100 cm
2
 is required. 
3.
 
If the room has a door that opens directly to the outside, and the room exceeds 1 m
3
 no air 
vent is required. 
4.
 
For room volumes between 5 m
3
 and 10 m
3
 an air vent of 50 cm
2
 is required. 
5.
 
If there are other fuel burning appliances in the same room B.S. 5440 part 2 1989 should 
be consulted to determine the air vent requirements. 
6.
 
This appliance must not be installed in a bed sitting room of less than 20 m
3
 or in a 
bathroom or shower room. 
Windows and permanent vents should therefore not be blocked or removed without first 
consulting a Corgi gas installer. 
Failure to install appliances correctly is dangerous and could lead to prosecution. 
 