Instructions for the installer 
 
 
3.
 
ADAPTATION TO  DIFFERENT TYPES  OF  GAS 
 
 
 
 
 
Before performing any cleaning or maintenance work, disconnect the appliance from the 
mains.
 
 
The cooker hob is preset for natural gas G20 (2H) at a pressure of 20 mbar. In the case of 
operation with other types of gas the burner nozzles must be changed and the minimum flame 
adjusted on the gas taps. To change the nozzles, proceed as described below. 
 
 
 
3.1
 
Replacement of nozzles on the hob 
 
This operation requires no primary air regulation. 
1.
 
Extract the grids and remove all the caps and flame-spreader crowns; 
2.
 
unscrew the burner nozzles with a 7 mm socket wrench; 
3.
 
replace the nozzles according to the type of gas to be used and the description in 
paragraph "3.2 Burner and nozzle characteristics table". 
4.
 
Replace the burners in the correct position. 
 
 
 
 
 
 
 
9