Whirlpool UMV1160C Leaflet

Page of 2
*Overall depth of product will vary slightly depending on door 
design.
29
⁷⁄₈
" (76.0 cm)
17
¹⁄₈
"
(43.5 cm)
+/-
³⁄₁₆
"
(0.5 cm)
16
¹⁄₄
"
(41.3 cm)
Up to 
16
³⁄₄
"
(42.5 cm)
*
PRODUCT MODEL NUMBERS
PRODUCT DIMENSIONS
Electrical: A 120-Volt, 60-Hz, AC-only, 15- or 20-amp fused electrical
supply with a fuse or circuit breaker. A time-delay fuse or time-delay circuit
breaker is recommended. It is recommended that a separate circuit serving
only this microwave oven be provided.
Microwave Hood Combination
Because Whirlpool Corporation policy includes a continuous commitment to improve
our products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only. For complete details, see Installation
Instructions packed with product. Specifications subject to change without notice.
Ref. W10724866A
12/12/14
CABINET OPENING DIMENSIONS
12" (30.5 cm) min.
14" (35.6 cm) max.
30"
(76.2 cm)
min.
A                   B
upper cabinet and 
side cabinet depth
30"
(76.2 cm)
typical*
66" (167.6 cm) min.
The grounded 3-prong outlet must be inside the upper cabinet.
A. 2" x 4" wall stud
B. Grounded 3-prong outlet
*30" (76.2 cm) is typical for 66" (167.6 cm) installation height. 
Exact dimensions may vary depending on type of range/cooktop below.
UMV1160C
VENTING REQUIREMENTS
This section is intended for architectural designer and builder/contractor reference only.
NOTES:
● 
Vent materials needed for installation are not provided with microwave hood
combination.
● 
We do not recommend using a flexible metal vent.
● 
To avoid possible product damage, be sure to vent air outside, unless using
recirculation installation. Do not vent exhaust air into concealed spaces, such as
spaces within walls or ceilings, attics, crawl spaces or garages.
For optimal venting installation, we recommend:
● 
using roof or wall caps that have back draft dampers 
● 
using a rigid metal vent 
● 
using the most direct route by minimizing the length of the vent and number of elbows
to provide efficient performance 
● 
using uniformly sized vents 
● 
using duct tape to seal all joints in the vent system 
● 
using caulking compound to seal exterior wall or roof opening around cap 
● 
not installing 2 elbows together, for optimal hood performance 
If venting through the wall, be sure that there is proper clearance within the wall for the
damper to open fully.
If venting through the roof, and rectangular to round transition is used, be sure there is
at least 3" (7.6 cm) of clearance between the top of the microwave oven and the
transition piece. See “Rectangular to Round Transition” illustration.
Roof venting
Roof cap
Wall venting
Wall cap
Page 1 of 2