Bertazzoni X304PIRCR User Manual

Page of 48
 
21
 
 
GAS BURNERS DATA TABLES 
 Models X304PIRX 
 
[M7S0PTU(4,6)X(2,5)D] 
Models X304PIRBI 
[M7S0PTU(4,6)W(2,5)D] 
Models X304PIRCR  
[M7S0PTU(4,6)D(2,5)D] 
Models X304PIRGI 
 
[M7S0PTU(4,6)I(2,5)D] 
Models X304PIRRO 
 
[M7S0PTU(4,6)R(2,5)D] 
Models X304PIRVI 
 
[M7S0PTU(4,6)L(2,5)D] 
Models X304PIRVE 
 
[M7S0PTU(4,6)V(2,5)D] 
Models X304PIRBL 
 
[M7S0PTU(4,6)U(2,5)D] 
Models X304PIRNE 
 
[M7S0PTU(4,6)N(2,5)D] 
 
Burner Position Injector  Gas Pressure 
Max Rate 
Min Rate 
By‐pass 
  
diam. 
[mm.] 
Type 
[i.w.c.] 
[BTU/h]
[W] [BTU/h] 
[W]  diam. 
[mm] 
Auxiliary 
Rear L  
0,90 
NG 
4” 
3400 
996 
900 
264 
Regulated 
  
0,54 
LP 
(Propane) 
11” 
3400 
996 
900 
264 
0,29 
Semi‐Rapid Front 
1,18 
NG 
4”  6100 
1787
1500  439 Regulated 
  
0,70 
LP 
(Propane) 
11” 
6100 
1787
1500 
439 
0,36 
Rapid Rear 
R 1,55  NG  4” 
10400 
3047
2500 
732 
Regulated 
  
0,92 
LP 
(Propane) 
11” 
10400 
3047
2500 
732 
0,47 
 
Front L Inner 
0,80 
NG 
4” 
2800 
820 
900 
264 
Regulated 
Dual Burner 
 
0,49 
LP (Propane) 
11” 
2800 
820 
900 
264 
0,29 
 
Front L Outer 
N°2 x 1,15 
NG 
4” 
12000  3516
4500 
1318 
Regulated 
 
 
N°2 x 0,70 
LP (Propane) 
11” 
12000  3516
4500 
1318 
0,65