Instructions for the installer 
 
 
 
 
The connection to the mains shall be done conforming to the regulations 
in force. Check that the power line is adequately grounded. Do not use 
reducers, adapters or shunts. On the power line, install an omnipolar cut-
off device with contact cut-off distance greater than or equal to 3 mm
located in an easily accessible position near the unit. 
 
The connection terminals are 
located at the rear of the 
appliance. For electrical 
connections see following 
diagram. To access, remove 
the rear cover. 
 
 
 
 
 
For operation on 380-415V3N
: use 
an H05RR-F-type five-core cable (5 x 
1.5 mm
2
). 
 
 
 
 
For operation on 380-415V2N
: use 
an H05RR-F-type four-core cable (4 x 
2.5 mm
2
). 
 
 
 
 
 
 
For operation on 220-240V
use an 
H05RR-F-type three-core cable (3 x 4 
mm
2
). 
 
The cable end to be connected to the 
appliance must be provided with an 
ground wire (yellow-green) at least 20 
mm longer.
 
 
 
 
 
 
The manufacturer declines all responsibility for damage to persons 
or things caused by non-observance of the above prescriptions or by 
interference with any part of the appliance. 
 
 