Smeg CS120A-6 User Manual

Page of 36
 
Instructions for the installer 
 
 
 
3.
  ADAPTATION TO DIFFERENT TYPES OF GAS 
 
 
 
 
Before performing any cleaning or maintenance work, switch off the 
power supply to the appliance. 
 
The cooking hob of the cooker is preset for G20 natural gas at a 
pressure of 20 mbar. In the case of functioning with other types of gas the 
burner nozzles must be changed and the minimum flame adjusted on the 
gas taps. Replace the burner nozzles as indicated in the table of the gas 
to be used. 
 
3.1
 Changing nozzles 
1.
  Extract the grids and remove all the caps and flame-spreader 
crowns; 
2.
  unscrew the burner nozzles with a 7 mm socket wrench; 
3.
  proceed with replacing the burner nozzles in accordance with the 
table for the gas in question. 
 
 
47