APC H10 User Manual

Page of 25
- 13 -
Technical Specifications
The following table contains the specifications for the H10.
Item
Specification
INPUT
Input Voltage Range for Opera-
tion (on utility)
92V - 145V
Nominal Voltage
120 Vac
Allowable Input Frequency for 
Operation (on utility)
47 - 63 Hz
Rated Input Current
12 Amps
Input Circuit Breaker Rating
15 Amps
OUTPUT
Number of Outlets
12 (all outlets are surge pro-
tected, conditioned, and regu-
lated)
Outlet type
NEMA 5-15R
Rated VA Capacity
1000VA
Rated Watt Capacity (continuous)
1000 Watts
Rated Output Current
12 Amps
SURGE PROTECTION
Let-Through Voltage Rating
<40 Volts
Peak Surge Current (NM + CM)
230KA
Data Line Protection Jacks (split-
ter)
Single-line 2-wire phoneline 
protection for phone, modem, or 
fax.
Coax
MISCELLANEOUS
DC Trigger
Two 3.5mm mini-jack plugs 
(5-30V)
EMI/RFI
40-100dB at 100KHz-30MHz
Total Surge Joules
4720