Environmental Requirements
For proper operations, the MERLIN Messaging System installation site must meet the
environmental requirements described in the table below.
Condition
Requirement
Relative Humidity
15% - 90% non-condensing
Temperature Range 32° F to 122° F (0° C to 50° C)
Air Quality
Dust-free area (preferably in an office environment)
Environment
No exposure to liquids. Avoid areas near drinking fountains, coffee makers, etc.
Power Supply
For the USA, Canada and other countries that use a USA-type outlet (nominal voltage 117
VAC), the communications system must have a 391A3 or newer power supply module
installed in the same carrier in which the MERLIN Messaging System module is installed.
In countries with nominal voltage of 220 VAC, a 391B2 or newer power supply module is
required in the same carrier in which the MERLIN Messaging System module is installed.
 