Datalogic Scanning 400 User Manual

Page of 142
RAPID CONFIGURATION 
 
1
 
1
1  RAPID CONFIGURATION 
 
 
STEP 1 – ASSEMBLE THE READER 
 
The first step to perform is to assemble the accessories that make up the Matrix 
400™
 
reader. The lens and either an internal or an external illuminator must be used. This 
procedure shows an internal illuminator. 
 
 
CAUTION 
Matrix 400™ must be disconnected from the power supply during this 
procedure. 
 
1.  In a dust-free environment, remove the Matrix 400™ Lens Cover by unscrewing it. 
 
 
CAUTION 
Do not touch the sensor aperture, lens glass or lens cover glass. These 
areas must be kept clean. Avoid any abrasive substances that might damage 
these surfaces during cleaning. 
 
2.  Remove the sensor protection label by pulling it off of the base. 
3.  Mount the lens by screwing it tightly onto the base. 
4.  If using an internal illuminator: 
a.  Mount the 4 internal illuminator spacers into the holes provided on the base. 
b.  Align and mount the Illuminator board tightly onto the spacers using the 4 screws 
provided in the illuminator package. The spacers are positioned asymmetrically to 
avoid incorrect alignment. 
5.  To keep dust and dirt off of the lens during mounting, temporarily replace the lens cover. 
 
 
Figure 1 – Assembling Matrix 400™ Accessories 
 
 
Locking Knobs
Internal 
Illuminator 
Lens Cover 
Illuminator Spacers