Datalogic Scanning 400 User Manual

Page of 142
RAPID CONFIGURATION 
 
3
 
1
CBX100/CBX500 Pinout for Matrix 400™ 
 
The table below gives the pinout of the CBX100/CBX500 terminal block connectors. Use this 
pinout when the Matrix 400™ reader is connected by means of the CBX100/CBX500: 
 
CBX100/500 Terminal Block Connectors 
Input Power 
Outputs 
Vdc 
Power Supply Input Voltage + 
+V 
Power Source - Outputs 
GND 
Power Supply Input Voltage - 
-V 
Power Reference - Outputs 
Earth 
Protection Earth Ground 
O1+ 
Output 1 + 
 
 
O1- 
Output 1 - 
Inputs 
O2+ 
Output 2 + 
+V 
Power Source – External Trigger 
O2- 
Output 2 - 
I1A 
External Trigger A 
(polarity insensitive)
 
Auxiliary Interface 
I1B 
External Trigger B 
(polarity insensitive)
 
TX 
Auxiliary Interface TX 
-V 
Power Reference – External Trigger 
RX 
Auxiliary Interface RX 
+V 
Power Source – Inputs 
SGND 
Auxiliary Interface Reference 
I2A 
Input 2 A 
(polarity insensitive)
 
ID-NET™ 
I2B 
Input 2 B 
(polarity insensitive)
 REF 
Network 
Reference 
-V 
Power Reference – Inputs 
ID+ 
ID-NET™ network + 
Shield 
ID- 
ID-NET™ network - 
Shield  Network Cable Shield 
 
 
Main Interface 
 
RS232 
RS485 Full-Duplex 
RS485 Half-Duplex 
 TX 
TX+ 
RTX+ 
 RTS 
TX- 
RTX- 
 RX 
*RX+  
 CTS 
*RX-  
 SGND 
SGND 
SGND 
 
* Do not leave floating, see par. 4.2.2 for connection details. 
 
 
 
CAUTION 
Do not connect GND, SGND and REF to different (external) ground 
references. GND, SGND and REF are internally connected through filtering 
circuitry which can be permanently damaged if subjected to voltage drops 
over 0.8 Vdc.