Rinnai RHFE-750ETRA User Manual

Page of 40
 
Rinnai Corporation RHFE-750ETRA                                                           25 
6.  Unscrew the flue access panel held by two 
screws located inside the top left hand corner of 
the appliance.  Slide this panel to the right behind 
the convection fan. 
  Connections 
   
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
1.  Carefully remove the packaged ceramic logs and 
place in a safe location. 
2.  To ensure the correct positioning, terminate the 
gas supply so that it is 5.9 inches (150 mm) from 
the front of the enclosure. 
3.  Gain access to the gas connection by removing 
the right hand side access panel and by 
unscrewing the four retaining screws.  Pry the 
front edge of the panel open to the right and pull 
forwards.   
4.  Position the appliance in front of the enclosure so 
that the end of the gas supply aligns with the gas 
fitting opening.  Connect the flexible gas 
connection to the gas supply. 
5.  Replace the right hand panel and secure with the 
four retaining screws. 
7.  Remove the 2 screws attaching the cover on the 
junction box.  Install the power cord flex clamp by 
inserting the threaded part through the bottom 
hole and attaching the washer.  Attach the 
electrical connection and place in the junction 
box.  Attach the cover with 2 screws. 
8.  Leak test the gas connection using a soapy 
solution.  Do not allow the soapy solution to 
contact electrical components.  Remove any 
residue. 
gas fitting opening 
gas connection 
remove 4 
screws to 
remove 
side 
panel