Design Dynamics VTD-18N-PDG User Manual

Page of 24
www.desatech.com
111826-02J
18
tROUBLESHOOtING
Continued 
 WARNING: If you smell gas
•  Shut off gas supply.
•  Do not try to light any appliance.
•  Do not touch any electrical switch; do not use any phone in your 
building.
•  Immediately call your gas supplier from a neighbor’s phone. Fol-
low the gas supplier’s instructions.
•  If you cannot reach your gas supplier, call the fire department.
IMPORTANT:
 Operating heater where impurities in air exist may create odors. Cleaning supplies, paint, 
paint remover, cigarette smoke, cements and glues, new carpet or textiles, etc., create fumes. These 
fumes may mix with combustion air and create odors. These odors will disappear over time.
POSSIBLE CAUSE
1. Heater burning vapors from 
paint, hair spray, glues, clean-
ers, chemicals, new carpet, 
etc. (See IMPORTANT state-
ment above)
2. Low fuel supply (propane/LP 
only)
3. Gas  leak.  See  Warning 
statement at top of page
1. Not enough fresh air is avail-
able
2. Low line pressure
3. ODS/pilot  is  partially 
clogged
1. Gas  leak.  See  Warning 
statement at top of page
2. Control valve or gas control 
defective
1. Foreign matter between con-
trol valve and burner
2. Gas  leak.  See  Warning 
statement at top of page
REMEDY
1. Open flue to maximum. Stop 
using odor causing products 
while heater is running
2. Refill supply tank (propane/LP 
only)
3. Locate and correct all leaks 
(see Checking Gas Connec-
tions, page 9)
1. Open window and/or door for 
ventilation
2. Contact local natural or pro-
pane/LP gas company
3. Clean ODS/pilot (see Cleaning 
and Maintenance, page 14)
1. Locate and correct all leaks 
(see Checking Gas Connec-
tions, page 9)
2. Replace control valve or gas 
control
1. Take  apart  gas  tubing  and 
remove foreign matter
2. Locate and correct all leaks 
(see Checking Gas Connec-
tions, page 9)
OBSERvED PROBLEM
Heater  produces  unwanted 
odors
Heater  shuts  off  in  use  (ODS 
operates)
Gas odor even when control knob 
is in OFF position
Gas odor during combustion