Alliance Laundry Systems Clothes Dryer User Manual

Page of 92
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Vending
27
512686
Table 6 (continued)
Models Starting Serial No. 0909
Total Cycle Time = Heat Time + Cool Down Time
Table 6 
Test Setting
When testing coin slide operation or other 
troubleshooting, set dipswitch with this shorter cycle:
1. Unplug the machine power cord.
2. Record the machine control dipswitch settings. 
Then set them all to the off position. Refer to 
3. Plug in the machine and initiate a cycle.
NOTE: With all the control dipswitches off, the 
total cycle time will be four minutes long.
4. Once all the testing is complete, unplug the 
machine and re-set the dipswitches to their 
original settings.
5. Plug in the machine.
Figure 25 
Cool Down Per Cycle
Cool Down 
Switch Number
Cycle Reset 
Switch Number
(in minutes)
7
8
3 (preset at factory)
OFF
OFF
6
ON
ON
DRY2225P
DRY2225P
1 2 3 4 5 6 7 8
O
N