Try the following:
 
Check to see if a household fuse has blown or circuit breaker 
has tripped. Electric dryers use two household fuses or 
breakers. Replace the fuse or reset the circuit breaker. 
Confirm the power cord is properly installed. Refer to “Electrical 
Connection” for details.
Select a Timed Dry heated cycle, and restart the dryer.
If the message persists, consult a qualified electrician.
“AF” (low airflow condition):
 
The dryer will continue to run when this diagnostic code is 
present. Press any key to clear the code from the display and 
return to the estimated time remaining.
Try the following:
Clean lint screen. 
Check to see if the vent run from the dryer to the wall is 
crushed or kinked. 
Confirm the vent run from the dryer to the wall is free of lint 
and debris.
Confirm the exterior vent exhaust hood is free of lint and 
debris.
Confirm your vent system falls within the recommended run 
length and number of elbows for the type of vent you are 
using. Refer to “Plan Vent System” for details.
Select a Timed Dry heated cycle, and restart the dryer.
If the message persists, have your entire home venting run 
cleaned.
“E” Variable (E1, E2, E3) service codes:
 
Call for service.
Dryer Results
Clothes are not drying satisfactorily, drying times are too 
long, or load is too hot
Is the lint screen clogged with lint? 
 
Lint screen should be cleaned before each load. 
WARNING
Fire Hazard
Use a heavy metal vent.
Do not use a plastic vent.
Do not use a metal foil vent.
Failure to follow these instructions can result in death 
or fire.
Is the exhaust vent or outside exhaust hood clogged with 
lint, restricting air movement?
 
 
Run the dryer for 5-10 minutes. Hold your hand under the 
outside exhaust hood to check air movement. If you do not feel 
air movement, clean exhaust system of lint or replace exhaust 
vent with heavy metal or flexible metal vent. See the Installation 
Instructions.
Are fabric softener sheets blocking the grille? 
 
Use only one fabric softener sheet, and use it only once.
Is the exhaust vent the correct length? 
 
Check that the exhaust vent is not too long or has too many 
turns. Long venting will increase drying times. See the 
Installation Instructions. 
Is the exhaust vent diameter the correct size? 
 
Use 4" (102 mm) diameter vent material.
Is the dryer located in a room with temperature below 45ºF 
(7ºC)?
 
 
Proper operation of dryer cycles requires temperatures above 
45ºF (7ºC).
Is the dryer located in a closet? 
 
Closet doors must have ventilation openings at the top and 
bottom of the door. The front of the dryer requires a minimum of 
1" (25 mm) of airspace, and, for most installations, the rear of the 
dryer requires 5" (127 mm). See the Installation Instructions.