Datalogic Scanning M8300 User Manual

Page of 212
POWERSCAN
®
 M8300 SYSTEM AND NETWORK LAYOUTS 
 
21
 
3.2  MULTIDROP STAR-SYSTEM™ NETWORK LAYOUTS 
 
Even though many stand-alone systems can operate in the same physical area without 
interfering with each other, it may be desirable to bridge data from multiple base 
stations in a network to a single Host. PowerScan
®
 M8300 readers are compatible with  
STAR-System™ networks. These networks provide seamless active roaming for any 
RF reading device in the system. 
 
 
3.2.1 
Host Master Layout 
 
 
 
A. 
Host Master with STAR-Link™ 
B. STAR-Box™ 
converter 
C. BC-8060 
slave 
cradles 
D.  STARGATE™ base stations 
Example Multidrop STAR-System™ Network with Host as Master 
 
In this layout the Host acts as the Master using STAR-Link™ software. The Host is 
connected in RS-232 to a STAR-Box™ converter, which is connected to the first slave 
in the RS-485 network. In this way the base stations provide communications between 
a single Host and all readers in the system. STARGATE™ base stations are used as 
slaves in this network. The Slaves at the ends of the network must be terminated (see 
the STARGATE™ and STAR-Box™ Installation Manuals and par. 2.8.3). 
See par. 4.6 and 4.7 or the Datalogic Aladdin™ Help On-Line for system 
configuration specifications. 
Internal 
Termination
Internal 
Termination 
RS-485 + VDC 
RS-485 + VDC 
RS-232
B
C
D
RS-485 Only 
CAB-428 Splitter