 M8300 SYSTEM AND NETWORK LAYOUTS 
 
23
 
3.2.3 
Master BC-8060 Network Troubleshooting 
 
Two diagnostic strings can be sent via RS-232 from the Host to the Master cradle in 
order to have feedback about the network itself. 
 
#+LSlave 
Returns a list of all the Slaves recognized at boot up. 
 
Example: 
In a network where the Master cradle has address 0188 and one Slave cradle with 
address 0001, the response is: 
 
 188 
   1
 
 
 
#+Alive<xxxx> 
Executes a continuous Alive request to the slave xxxx in order to monitor the 
performance of the connection. A diagnostic message is displayed on the Host. 
 
Example: 
If this command is sent for slave cradle with address 0032, the response is: 
 
/*32: BC-80X0 SOFTWARE RELEASE 1.00 20/10/2006*/
 
if there are no communication errors 
 
/*32: FAIL*/ 
if there are communication errors. 
 
To exit from this command, reset the system by cycling power to the Master cradle.