Pin 6 Not used. 
 
 
CONNECTOR 5 
 
Pin 1 Orange- Factory alarm re-arm 250mA (-) negative output. This is an optional 
output that will provide a (-) negative pulse output during lock, after crank and after 
ignition shut down.  
 
Pin 2 Orange/White- Factory alarm disarm 250mA (-) negative output. This is an 
optional output that will provide a (-) negative pulse output during unlock and 
before ignition is turned on. 
    
Pin 3 Violet- Dome light 250mA (-) negative output. This is an optional output that will 
provide a 30 second (-) negative output after system is unlocked for dome-light 
supervision. 
 
Pin 4 Brown- Siren 12-volt (+) positive output. This wire will provide a 30 or 60 second 
(+) positive output for the external siren. (Note: Factory default is 30 seconds.) 
 
Pin 5 White- Horn honk 250mA (-) negative output. This is an optional output that will 
provide a 30 or 60 second (-) negative pulse when the alarm is triggered or during 
panic. 
 
Pin 6 Yellow- Aux 1- 250mA (-) negative output. This is an optional output that will 
provide a pulse, latch or a timed pulse output. (Note: Options programmer is 
required to program a timed pulse output.) 
 
Pin 7 Yellow/White- Aux 2- 250mA (-) negative output. This is an optional output that 
will provide a pulse, latch or a timed pulse output. (Note: Options programmer is 
required to program a timed pulse output.) 
 
Pin 8 Not used. 
 
 
CONNECTOR 6 
(Pre-wired L.E.D.) 
 
Pin 1 Black-L.E.D. - (-) negative output.  
 
Pin 2 Black/White - 3-volt L.E.D. (+) positive output.