Pin 5 Blue/Black- Lock 250mA (-) negative output. This wire will provide a (-) negative 
pulse output during lock. (Note: Positive and reverse polarity will require additional 
relays. 
 
Pin 6 Not used. 
 
 
 
CONNECTOR 5 
(Optional Temperature sensor)
 
 
Pin 1 Gray-12-volt (+) positive output. This wire will provide 12-volt (+) positive to 
temperature sensor. 
 
Pin 2 Brown-Temp sensor (-) negative input. This wire will activate remote start when 
provided a (-) negative input. (Note: If vehicle is remotely started, a (-) negative 
input will turn the vehicle off.) 
 
Pin 3 Black-Temp sensor (-) negative ground output. 
 
 
CONNECTOR 6 
(Pre-wired Antenna Cable)
 
 
Pin 1 Yellow-RX input. This wire receives signal from remote. 
 
Pin 2 White-TX output. This wire transmits signal to remote. 
 
Pin 3 Red-12-volt constant (+) positive input. 
 
Pin 4 Black- (-) negative ground input. 
 
 
 
CONNECTOR 7 
RS 232
 
 
Pin 1 Yellow-RX input. This wire receives signal from remote. 
 
Pin 2 Blue-TX output. This wire transmits signal to remote. 
 
Pin 3 Black-(-) negative ground in 
 
Pin 4 Red-12-volt constant (+) positive input.