5-4.2.1. Connection of Composite Monitor   
If necessary, connect the composite Video Output (yellow RCA) and Audio Output (white 
RCA) to Video IN and Audio IN on a composite monitor or TV (RCA cable: not included). 
 
5-4.3. Sensor Connection and RELAY IN &OUT   
    SENSOR Connection (SENSOR IN)   
     
Connect up to 8 sensors to ALM (SENSOR) IN. The Sensors should be contactor type and 
support N.O. (Normal Open).   
 
 
 
 
 
[Fig. 5-6 SENSOR IN PIN] 
 
  ALARM OUT Connection 
  When necessary, use ALARM OUT. The ALARM OUTPUT is a relay contactor type and 
  supports N.O. (Normal Open) and N.C. (Normal Close). The Output capacity is 220V 1A. A 
  higher capacity can cause system failure.   
 
 
 
 
 
 
 
 
[Fig. 5-7 Alarm Output] 