Lucent Technologies 555-661-150 User Manual

Page of 360
MERLIN LEGEND Communications System Release 6.1
Network Reference  
555-661-150  
Issue 1
August 1998
Security 
Page 4-6
Facility Restriction Levels and Remote Access 
4
Extensions. The factory-set FRL for extensions is 3. When an extension 
user attempts to use ARS or make a UDP call on his or her local system, 
the extension FRL is compared to the local ARS or UDP route FRL. In 
order for the call to go through, the extension FRL must be equal to or 
greater than the route FRL.
VMI Ports. The factory-set FRL for VMI ports is 0.
Remote Access Default Class-of-Restriction. The factory-set FRL for 
Remote Access is 3. To allow routing of calls through a system in a 
network, the local system manager assigns an FRL and other restrictions 
to a class of trunks, using remote access programming. This operation is 
described in the next topic.
Remote Access Default 
Class-of-Restriction Settings
4
All remote access COR settings are applied in networked systems for the 
following calls:
UDP and ARS calls that arrive on tandem trunks from another networked 
system and are routed to another system or to the PSTN.
Remote access calls that arrive at a local system on a public-switched 
network DID trunk or PRI dial-plan routed facility.
Remote access calls that are made by entering a Remote Access code that 
has been included in the non-local dial plan of the calling system.
In Release 6.1 and later systems, calls that arrive on lines assigned to a 
calling group with a non-local member that are routed to a remote system.
The Remote Access COR settings must be planned and implemented carefully to 
permit ARS and UDP extension calls across the network as appropriate, while 
prohibiting remote access calling that might violate an organization’s security 
needs. 
NOTE:
When remote access is explicitly assigned to a loop-start or ground-start 
trunk or to a PRI facility routed by line appearance, that line/trunk is 
assigned to remote access, and default COR settings do not apply if barrier 
codes are required. The remote access user calls into the system on this 
type of facility and enters the barrier code, if required, just as they do in 
non-networked systems. The 
Feature Reference describes this operation.
SECURITY
l
ALERT:
!
If barrier codes are not required, these calls receive default COR for non-tie 
trunks. If the system uses tandem PRI trunks for ARS to route calls through 
the system, then the calling restriction option of the default COR must be set 
to unrestricted. This can lead to toll fraud.