Lucent Technologies 555-661-150 User Manual

Page of 360
MERLIN LEGEND Communications System Release 6.1
Network Reference  
555-661-150  
Issue 1
August 1998
Network Management 
Page 5-19
Switch Identifiers 
5
Switch Identifiers
5
If your system uses private tandem trunks, you 
must program switch identifiers. 
Switch identifiers are 1- or 2-digit numbers that are used by the system to identify 
transmission levels and check routing. Switch identifiers indicate the switch 
connected to the far end of a local private trunk.
Switch identifiers appear in print reports. You can use Next to see the switch 
identifiers for all trunks. To see a report showing switch identifiers, select the 
3ULQW
 option on the System Programming menu and then choose
7UXQNLQIR
 
and 
*HQHUD
l. See Appendix B for an example of the General Trunk Information 
report. The switch identifier appears in the “Extern Switch” column.
Planning Guidelines
5
The procedures in this topic allow you to add, change, and remove switch 
identifiers.
PSTN trunks connected to your local system do not require identifiers. They are, 
by default, not assigned an identifier.
When a private networked trunk is deleted, either via DS1 programming or by the 
Board Renumber procedure, all switch identifiers in the system need to be 
examined and reprogrammed as needed. Newly added private network trunks 
need to be programmed with new switch identifiers.
You can assign a switch identifier to a block of trunks. You can also remove a 
switch identifier from a block of trunks that use the same switch identifier. 
The correct switch identifier for a trunk or block of trunks is determined by the type 
of switch to which the trunk is connected and whether or not that switch is a 
satellite switch (located within 200 miles of the local system). It is important to 
know the distance between systems in order to assure transmission quality. The 
identifiers are switch numbers that have the following meanings:
Unassigned, no value = trunk connected to CO (central office)
1–20 = trunk connected to a non-satellite MERLIN LEGEND 
Communications System
21–40 = trunk connected to a satellite MERLIN LEGEND Communications 
System
41–50 = trunk connected to a non-satellite system that is not a MERLIN 
LEGEND Communications System (for example, a DEFINITY ECS)
51–60 = trunk connected to a satellite system that is not a MERLIN 
LEGEND Communications System (for example, a DEFINITY ProLogix 
Solutions communications system)