Lucent Technologies 555-661-150 User Manual

Page of 360
MERLIN LEGEND Communications System Release 6.1
Network Reference  
555-661-150  
Issue 1
August 1998
Network Management 
Page 5-22
Tandem PRI Facilities 
5
Tandem PRI Facilities 
5
This topic presents considerations for managing tandem PRI facilities connected 
to your local system in a private network.
If your system includes PSTN PRI facilities that route calls to non-local 
extensions, you also need to consult the procedures in the “Dial Plan Routing” 
topic of “PRI Facilities,” 
System Programming. You can, if necessary, delete all the 
digits from PRI calls received on a system and substitute the non-local extension 
number (calling group number, for example) required for routing across the private 
network.
When you order facilities for PRI, you specify a T1 point-to-point circuit; the 
service provider may supply amplification but not PRI service or switching. 
Program the circuit for PRI, following the instructions in 
System Programming for 
both DS1 and PRI. Tandem PRI trunks should be programmed for Extended 
Superframe (ESF) format, which detects errors more reliably than other formats. 
In addition, tandem PRI trunks should be programmed for bipolar 8 zero 
substitution (B8ZS) line coding. If alternate mark inversion (AMI) line coding is 
used, 64-kbps data calls (128 kbps for 2B data) are not supported. If D4 framing is 
used maintenance is more difficult. The framing and line coding must be verified 
with the service provider. However, 56-kbps data calls are supported (112 kbps for 
2B data). 
NOTE:
Verify that any Channel Service Unit (CSU) on the DS1 circuit between the 
MERLIN LEGEND Communications System and the PSTN is programmed 
for the same framing as the DS1 slot on the MERLIN LEGEND 
Communications System.
You may place drop-and-insert equipment between systems connected by a PRI 
tandem facility, allowing use of fewer than 23 B-channels. Some channels are 
reserved in this way for non-MERLIN LEGEND communications, and the 
remaining are dedicated to MERLIN LEGEND voice/data traffic. The equipment 
must never drop Channel 24, the D-channel. All 24 channels still count toward the 
system maximum of 80 lines. For channels not used by the MERLIN LEGEND 
system, lines and B-channels must be removed from the B-channel group.
NOTE:
When connecting to a DEFINITY ECS or DEFINITY Prologix, the 
DEFINITY must provision all 23 B-channels and allow MERLIN LEGEND to 
take out of service any B-channels that were dropped, then DEFINITY can 
unprovision those channels.