MERLIN LEGEND Communications System Release 6.1
Network Reference  
555-661-150  
Issue 1
August 1998
Call-Handling Scenarios 
Page 2-13
Networking Guidelines 
2
UDP routing applies FRLs to calls over specific routes for pools of tandem 
trunks. A different set of FRLs is programmed for ARS routes. However, an 
extension’s FRL applies to 
both UDP routes and ARS routes. An 
extension’s FRL is applied only to local tandem and PSTN calls and is not 
carried across the private network when the caller uses ARS to direct a call 
to PSTN facilities on another switch. As you read the scenarios in this 
chapter, pay attention to the following rules:
— Within a system, ARS FRL restrictions compare the local extension FRL 
to the route FRL. To use a route for a call, the extension FRL must be 
equal to or greater than the route FRL.
— For intersystem calling, the system compares the local extension FRL to 
the UDP route FRL. To use a route for a call, the extension FRL must be 
equal to or greater than the UDP route FRL. 
— When a Remote Access code is included in the non-local dial plan of the 
calling system, the caller’s barrier code FRL on the called system is 
compared to the UDP or ARS route FRL on the called system.
— When a UDP or ARS call is routed into a system over tandem trunks and 
then out of it again, the FRL assigned to the default COR for all-tie or all 
non-tie trunks is compared to the FRL assigned to the outgoing UDP or 
ARS route on the called system. The default COR’s FRL must be 
greater than or equal to the FRL of the outgoing route on the called 
system.
— When a PRI dial-plan routed or DID call is routed across systems in a 
private network, the system receiving the call from the PSTN searches 
the local dial plan and then the non-local dial plan for the destination 
extension number. If the number is in the non-local dial plan, the call is 
routed out using the UDP routing pattern for the specified extension 
range. For a call to be routed out of the 
next receiving system, that 
system’s COR FRL must be equal to or greater than the UDP route FRL.
— In Release 6.1 and later, when an integrated VMI calling group is used 
for routing calls to a centralized VMS/AA, assign an FRL of 0 to the UDP 
route for the VMI conversion number. The pattern for the VMI 
conversion number should not be used for any other routing.
SECURITY
l
ALERT:
!
Networked systems require special attention to security issues. Follow the 
rules below when setting up and planning your system for private network 
use.
Ensure that barrier codes are required for incoming remote access 
calls received on PSTN dial-plan routed and tandem facilities that 
route to the Remote Access code (889, for example). When you 
program the default COR, turn the barrier code requirement on. This 
setting is ignored for ARS calls and calls to non-local extensions 
across the private network. However, it is still applied to DID and 
PRI dial-plan routed remote access calls as well as to calls received