Lucent Technologies 555-230-024 User Manual

Page of 362
System Management Solutions
555-230-024
14-8
Issue 5    January 1998 
administrators can control who uses terminal translation initialization — and 
when.
Scheduling 
DEFINITY ECS’s functional scheduling allows you to specify the time a command 
will be executed or to specify that it should be executed on a periodic basis. Only 
commands that do not require user interaction after being entering on the com-
mand line (such as list, display, test) can be scheduled.
DEFINITY ECS also supports scheduling of “one shot” requests — commands 
that are executed only once and then removed from the scheduling queue auto-
matically by the feature, such as 
save translation commands.
Functional scheduling enhances administration. For example, scheduling of save 
translations is particularly important when large numbers of translation changes 
are made during the day, ensuring that they will be saved to tape at the specified 
time. The “one shot” report is particularly useful for scheduling large print jobs at 
night that are normally run only once.
Basic Reporting 
DEFINITY ECS has built-in capabilities for generating reports required for small, 
medium, and large systems. These reports are available without special hard-
ware or software.
System Measurements reports supply information on the status of all communi-
cation facilities. These reports help determine the efficiency of resources, includ-
ing but not limited to trunk groups, hunt groups, and the attendant group.
System Status reports supply information associated with the attendant group, 
major and minor alarms, and traffic measurements.
The Recent Change History feature reports on the most recent 
administration and maintenance commands entered. DEFINITY ECS also 
supplies:
— New site data on the station form. New fields include the set color, 
building, floor, and headset. In addition, user-defined validation 
checks are provided for a subset of the site data items.
— Scaling enhancements, as well as a ranging and filtering capability, 
for large switches. These allow your system administrator to restrict 
data reporting to only the desired amount of switch parameters.
DEFINITY ECS also includes the following reports:
Class-of-Restriction report lists the extensions that have a particular Class 
of Restriction value or that fall within a range of Class of Restriction values.