9.1 Introduction 
Several options are available for use with Siemens Standard drives; some are 
described below.  These are intended to assist product selection, installation and 
commissioning in certain applications. 
9.2 
Advanced Operating Panel AOP 
The advanced operating panel consists of a control and display unit that fits directly 
on top of the MICROMASTER or MIDIMASTER Control panel.  A socket connects 
directly onto the front of the unit, so the AOP can take power from and 
communicate with the drive via the RS485 interface. 
The AOP offers the following features: 
√=
Many languages (  Such as English, German, French, Italian, Spanish) for  text 
operation with explanation of parameters, faults etc. 
√=
Diagnostics - help with fault finding. 
√=
Upread/download of parameter sets from units to AOP and back. This allows 
fast, reliable programming and copying of parameter sets. 
√=
AOP mounts directly on MICROMASTER and MIDIMASTER. 
√=
Optional Door mounting kit with IP54 protection included. 
√=
Optional AOP to computer connection kit  for remote operation and off line 
programming.  
The AOP has several practical uses; for example: 
·  The AOP may be mounted directly onto the inverter and used to control the 
drive directly.  
·  The AOP can be mounted on a separate panel (using an optional cable of up to 
5m) to enable remote control and monitoring of the drive. 
·  If an external power supply is connected to the AOP, remote control over 
distances greater than 5m is permissible 
·  Parameter sets can be stored in the AOP and uploaded or downloaded as 
required. This is particularly useful where many inverters require programming 
in production.