7 MICROMASTER 410 Specifications
MICROMASTER 410 Operating Instructions
6SE6400-5EA00-0BP0
63
7
MICROMASTER 410 Specifications
Table 7-1
MICROMASTER 410 Performance Ratings
Feature
Specification
Mains Operating Voltage &
Power Ranges
Power Ranges
100 to 120 V
±
10% 1AC
0.12 kW – 0.55 kW
200 to 240 V
±
10% 1AC
0.12 kW – 0.75 kW
Input Frequency
47 to 63 Hz
Output frequency
0 Hz - 650 Hz
Power Factor
≥
0.7
Inverter Efficiency
96 to 97 %
Overload Capability
Up to 150 % of rated output current for 60 seconds followed by 85 % of rated
output current for 240 seconds (cycle time 300 seconds)
output current for 240 seconds (cycle time 300 seconds)
Inrush Current
Less than rated input current
Control Method
Linear V/f ; Parabolic V/f; Flux Current Control (FCC); Multi-point V/f
Pulse Frequency
2 kHz to 16 kHz (2 kHz steps) 8 kHz Standard
Fixed Frequencies
3; programmable
Skip Frequencies
1; programmable
Setpoint Resolution
0.01Hz digital, 0.01 Hz serial, 10 bit analogue
(motor potentiometer 0.1 Hz)
(motor potentiometer 0.1 Hz)
Output Frequency Resolution
0.01 Hz digital, 0.01 Hz serial
Digital Inputs (PNP type)
3; freely programmable, non isolated, SIMATIC compatible
Analog Input
1; for setpoint (0 to 10 V, scalable or for use as 4
th
digital input)
Relay Output
1; parameterizable, 30 V DC / 5 A (resistive), 250 V AC / 2 A (inductive)
Serial Interface
RS-485, for operation with USS protocol
Electromagnetic Compatibility
Variant with integrated EMC filter according to EN 61800-3
Braking
DC braking and Compound braking
Protection Level
IP20
Operation Temperature
-10
°
C to +50
°
C
Storage Temperature
-40
°
C to +70
°
C
Humidity
95 % RH – non-condensing
Operational Altitudes
Up to 1000 m above sea level without derating
Protection Features
Undervoltage, Overvoltage, Overload, Ground Faults, Short circuit, Stall
Prevention, Motor Overtemperature, Inverter Overtemperature Protection
Prevention, Motor Overtemperature, Inverter Overtemperature Protection
Standards
UL, cUL, CE, C-tick
CE Marked
Conformity with EC Low Voltage Directive 73/23/EEC
and Electromagnetic Compatibility Directive 89/336/EEC
and Electromagnetic Compatibility Directive 89/336/EEC
Design/Manufacture
In accordance with ISO 9001