Siemens 611 User Manual

Page of 324
 
Description of the motor 
 
2.4 Order designation 
 
 
 
Note 
If, for design reasons, only individual components can be installed (stator and rotor 
separately), these can be ordered and shipped separately. 
 
 
 
DANGER 
 
Due to the risk of compression caused by the attractive forces of the rotor, an installation 
device must be provided by the customer when the stator and rotor are installed separately.
 
2.4.9 
Ordering examples 
Example 1: 
Stator and rotor preassembled with transportation locks; cooling jacket; axial cable outlet for 
SIMODRIVE 611 digital/universal HR drive system, power module 18 A / 36 A: 
MLFB 1FW6090–0PB15–1JC2 
Example 2: 
Stator and rotor preassembled with transportation locks; integrated cooling; radial cable 
outlet towards the outside for SIMODRIVE 611 digital/universal HR drive system, power 
module 18 A / 36 A: 
MLFB 1FW6190–0VB07–1JC2 
Example 3: 
Cooling connection adapter (axial/radial) for sizes 1FW616, 1FW619, and 1FW623: 
MLFB 1FW6160–1BA00–0AA0 
Example 4: 
Individual component/stator as spare part: MLFB 1FW6190–8VB07–1JD2 
Individual component/rotor as spare part: MLFB 1FW6190–8RA07–0AA0 
Individual component/round sealing ring as spare part MLFB 1FW6090–1EA00–0AA0 
(for size 1FW609) 
1FW6 Built-in torque motors 
Configuration Manual, 05/2009, 6SN1197-0AD00-0BP7 
39