User ManualTable of ContentsINTRODUCTION7SCOPE8ASSOCIATED DOCUMENTATION9PRODUCT9STANDARDS9PRODUCT HISTORY LOG10HARDWARE10SOFTWARE10GLOSSARY OF ABBREVIATIONS12GLOSSARY OF TERMINOLOGY13SYSTEM DESCRIPTION15OVERVIEW16GENERAL16DETECTOR CIRCUITS16DISPLAYS16OUTPUTS20POWER SUPPLY20REMOTE DISPLAY & PRINTER20NETWORKING20PHYSICAL STRUCTURE21SYSTEM STRUCTURE24PCB MODULES24INTER-CONNECTION & STRUCTURE26SYSTEM SPECIFICATIONS29GENERAL30FIP PART NUMBER & DESCRIPTION30SYSTEM EXPANSION30ENVIRONMENTAL31MECHANICAL SPECIFICATIONS31ELECTRICAL SPECIFICATIONS32MAINS SUPPLY32BATTERY CHARGER & PSU32BATTERY33FUSES33CURRENT CONSUMPTION34F3200 Quiescent & Alarm Currents34NDU Quiescent and Alarm Currents35INPUT SPECIFICATIONS36AZC SPECIFICATIONS36MAF/PSU INPUTS40CONTROLLER/DISPLAY INPUTS418 RELAY MODULE SUPERVISION41NZ MODE DISPLAY EXTENDER BOARD INPUTS41OUTPUT SPECIFICATIONS428 ZONE MODULE OUTPUTS428 RELAY MODULE OUTPUTS42MAF/PSU OUTPUTS43CONTROLLER/DISPLAY OUTPUTS45RS485 BOARD46NZ DISPLAY EXTENDER BOARD OUTPUTS46CONTROLS47DISPLAYS48ORDERING INFORMATION49ORDERING INFORMATION50CONFIGURING A FIP55GENERAL56MODULE CONFIGURATION56BATTERY & POWER SUPPLY57GENERAL57BATTERY/CHARGER CALCULATIONS58EXAMPLE BATTERY/CHARGER CALCULATIONS59BATTERY SIZE60BATTERY TEST RESISTORS61BATTERY OVERCURRENT PROTECTION63POWERING AN F3200 FROM AN EXTERNAL DC SUPPLY63LINKS ON PCB MODULES65CONTROLLER/DISPLAY65MAF/PSU658 RELAY MODULE6516 ZONE LED DISPLAY65ERROR MESSAGES DURING FIP CONFIGURATION66PROGRAMMING67INTRODUCTION68GENERAL68MENU STRUCTURE & PARAMETER ENTRY68PROGRAMMING KEYS76RECOMMENDED PROCEDURE FOR CONFIGURATION & PROGRAMMING76RECOMMENDED PROCEDURE FOR CONFIGURATION & PROGRAMMING (CONTINUED)77SET MENU & OPERATOR PROGRAMMING FUNCTIONS78GENERAL78VIEW DATA PARAMETERS78INITIALISING, ACCESSING, DE-ACCESSING, PRINTING, SAVING, LOADING & VERIFYING THE DATABASE79INITIALISING THE DATABASE79ACCESSING THE DATABASE79DE-ACCESSING THE DATABASE80PRINTING & SAVING THE DATABASE80RESTORING THE DATABASE FROM A COMPUTER81DATABASE CONVERSION82VERIFYING A SAVED DATABASE82PROGRAM DATA MENU, TEXT & GLOBAL PARAMETERS83GENERAL83ACCESS CODES83TEXT ENTRY84PROGRAMMING TEXT WITH THE KEYPAD84TEXT PROGRAMMING WITH A PC86GLOBAL DATA88PROGRAMMING SYSTEM CONFIGURATION103SYSTEM CONFIGURATION MENU104CONFIGURING CIRCUITS (AZCS)108GENERAL108ALARM TEXT108MODE108TIME DELAYS109VOLTAGE BANDS111CONFIGURING ZONES113GENERAL113MAPPING TO MAF113MAPPING ZONES TO LEDS113PROGRAMMING OUTPUTS115GENERAL115GENERAL (CONT’D)116LOGIC OPERATORS116LOGIC OPERANDS117Operands Type 1117Operands Type 2122EXAMPLES OF LOGIC EQUATIONS124ENTERING EQUATIONS126THE OUTPUT LOGIC PROGRAMMING MENUS128PROGRAMMING RELAYS129CONTROLLING ZONE LEDS130PROGRAMMING ZONE ISOLATE/DE-ISOLATE/RESET COMMANDS131ENTERING OUTPUT LOGIC ZONE COMMANDS131OPERATION OF OUTPUT LOGIC ZONE COMMANDS133EXAMPLE EQUATIONS133USING THE ZND AND ZNM TOKENS134RELAY SUPERVISION135GENERAL135BELLS & ANCILLARY RELAY SUPERVISION135MODULE RELAY SUPERVISION136RDU137INSTALLATION & WIRING139INSTALLATION140CABINET INSTALLATION140CARDFRAME INSTALLATION142MODULE INSTALLATION143LED DISPLAY INSTALLATION144ZONE LABELLING144FIELD WIRING146GENERAL146MAINS WIRING147AZC WIRING148MAF ANCILLARY RELAY WIRING150WARNING SYSTEM WIRING153MODULE RELAY WIRING158DUAL POLE – POLARITY REVERSAL OUTPUT159OPEN COLLECTOR WIRING160LED MIMIC DISPLAYS160INTERFACING TO OTHER EQUIPMENT160ASE INSTALLATION AND WIRING161RDU WIRING162SLIMLINE NDU (FP0714) WIRING164INSTALLATION OF 19" NDU (FP0733)164APPLICATIONS165AS1668 AIR CONDITIONING CONTROL166GENERAL166CIRCUITS & ZONES167RELAYS170LEDS171AS1668 CONTROL MODULE & DRAWINGS172GAS FLOOD177GENERAL177LOGIC & CONFIGURATION177NOTES179USE OF ACTUATORS180AVI SIGNS181DRAWINGS182SUB FIP MONITORING189GENERAL189CONNECTION190FIRE DETECTION IN HAZARDOUS AREAS (EXPLOSIVE ATMOSPHERES)192REFERENCES192GENERAL192INTRINSICALLY SAFE DETECTION193ISOLATED REPEATERS1936 TERMINAL ISOLATED REPEATER1954 TERMINAL ISOLATED REPEATER WITH ZONE ADAPTOR UNIT ZAU4011974 TERMINAL ISOLATED REPEATER ALONE200USE OF NORMALLY CLOSED CONTACTS202SPECIAL CONNECTIONS TO DETECTORS203CONNECTING THE S231I+ OR S231F+ (USING ZAU401 REV 2)203ALIGNMENT, ADJUSTMENT & PLACING INTO OPERATION205ALIGNMENT & ADJUSTMENT206PLACING INTO OPERATION207GENERAL207POWER UP208COMMISSIONING CHECKLIST209NETWORK PROGRAMMING211INTRODUCTION212PANELLINK NETWORK212NETWORK APPLICATION OVERVIEW212PROGRAMMING METHODS214DATA FILTERS - THE SID LIST & GROUPS LIST214NETWORK MAF STATUS214PROGRAMMING METHODOLOGY217NETWORK CONFIGURATION MENU219NETPG1 OPTIONS219NETPG2 OPTIONS219NETPG3 OPTIONS220NETPG4 OPTIONS220NETPG5 OPTIONS221SID CONFIGURATION222SID MENU ONE222SID MENU TWO223NETWORK MAF CONFIGURATION224OPTIONS UNDER NETMAF1224OPTIONS UNDER NETMAF2224OPTIONS UNDER NETMAF3224NET COMMANDS225NET FFCIF CONFIGURATION226NETWORK EVENT CONFIGURATION228NETWORK LOGIC VARIABLES230NET STATUS REFRESH231NDU OPERATION232DEFAULT VALUES FOR PANEL-LINK VARIABLES234NEW ZEALAND OPERATION237GENERAL238NZ DISPLAY EXTENDER BOARD238MANUAL CALLPOINT (MCP)240PROGRAMMABLE OPTIONS241LOGIC TOKENS242SYSTEM STATES & INDICATIONS243NETWORK PARAMETER PROGRAMMING244THE SID LIST245NETWORK MAF CONFIGURATION245NETWORK FFCIF CONFIGURATION245INSTALLATION : NZ DISPLAY EXTENDER BOARD & BRIGADE DISPLAYS246GENERAL246MIMIC DISPLAY246ACTIVE DISPLAY247DISPLAY EXTENDER BOARD MISCELLANEOUS TERMINATION248TANDEM LCD MODE255TANDEM LCD MODE256Size: 2.45 MBPages: 284Language: EnglishOpen manual