© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
70420801 (EN)
16
Installation
Pre-Installation Inspection
Upon delivery, visually inspect the crate, carton and 
parts for any visible shipping damage. If the crate, 
carton or cover is damaged or signs of possible 
damage are evident, have the carrier note the condition 
on the shipping papers before the shipping receipt is 
signed, or advise the carrier of the condition as soon as 
it is discovered.
Remove the crate and protective cover as soon as 
possible and check the items listed on the packing list. 
Advise the carrier of any damaged or missing articles 
as soon as possible. A written claim should be filed 
with the carrier immediately if articles are damaged 
or missing.
IMPORTANT: Warranty is void unless tumble 
dryer is installed according to instructions in this 
manual. Installation should comply with minimum 
specifications and requirements detailed in this 
manual and applicable local gas fitting regulations, 
municipal building codes, water supply regulations, 
electrical wiring regulations, and any other 
relevant statutory regulations. Due to varied 
requirements, applicable local codes should be 
thoroughly understood and all pre-installation 
work arranged for accordingly.
IMPORTANT: Keep tumble dryer area clear and 
free from combustible materials, gasoline and other 
flammable vapors and liquids.
Location Requirements
The tumble dryer must be installed on a level floor. 
Floor covering materials such as carpeting or tile must 
be removed.
To assure compliance, consult local building code 
requirements. The tumble dryer must not be installed 
or stored in area where it will be exposed to water and/
or weather.
IMPORTANT: DO NOT block the airflow at the 
rear of the tumble dryer with laundry or other 
articles. Doing so would prevent adequate air 
supply to the combustion chamber of the tumble 
dryer.
A typical tumble dryer enclosure is shown in Figure 1. 
Note the minimum and maximum dimensions. Local 
codes and ordinances must be complied with.
Materials Required (Obtain locally)
All Models
One Single Pole fused disconnect 
switch or circuit breaker on 1 Phase 
models.
Circuit breaker on 3 Phase models.
Gas Models
One gas shut-off valve for gas 
service line to each tumble dryer.
Steam Models
One steam shut-off valve for steam 
service line to be connected upstream 
of solenoid steam valve.
Two steam shut-off valves for each 
condensate return line.
Flexible steam hoses with a 125 psig 
(pounds per square inch gauge) 
(8.79 kg/sq. cm) working pressure 
for connecting steam coils. Refer to 
Figure 14 and Figure 15 or sizing 
and connection configurations.
Three steam traps for steam coil 
outlet to condensate return line.
Optional – Three vacuum breakers 
for condensate return lines.