GX1660 User Manual 
 
70-0057A-A
 
Allied Vision Technologies (Canada) Inc. 
 
 
9
 
 These signals only function as outputs and can be configured as follows: 
 
Exposing 
Corresponds to when camera is 
integrating light. 
Trigger Ready 
Indicates when the camera will accept a 
trigger signal. 
Trigger Input 
A relay of the trigger input signal used 
to “daisy chain” the trigger signal for 
multiple cameras. 
Readout 
Valid when camera is reading out data. 
Strobe 
Programmable pulse based on one of the 
above events. 
Imaging 
Valid when camera is exposing or 
reading out. 
GPO 
User programmable binary output. 
 
Any of the above signals can be set for active high or active low. 
RS-232 RXD and RS-232 TXD 
These signals are RS-232 compatible. These signals allow communication from the host system 
via  the  Ethernet  port  to  a  peripheral  device  connected  to  the  camera.  These  signals  are  not 
optically isolated and reference power ground.  If these signals are used in the system, care must 
be taken to prevent ground loop problems. 
USER GROUND 
This connection provides the user ground reference and return path for the isolated sync in and 
sync out signals.  This connection is necessary if any of the isolated sync signals are to be used.  
It is also recommended that this ground connection be physically close to the used sync signals 
to  prevent  parasitic  coupling.    For  example,  a  good  cable  design  would  connect  the  required 
signal on one conductor of a twisted pair and the isolated ground on the second conductor of the 
same twisted pair. 
USER VCC 
This  connection  provides  the  power  supply  for  the  isolated  sync  out  signals.    The  voltage 
requirement is from 5V to 24V DC. The current requirement for this supply is a function of the 
optical isolator collector current and the number of sync outs used in the system.  See the 
SYNC 
OUTPUT
  section  for  more  detail.  To  prevent  parasitic  coupling  this  connection  should  be 
physically close to the used SYNC OUT signals and USER GROUND.