GX1660 User Manual 
 
70-0057A-A
 
Allied Vision Technologies (Canada) Inc. 
 
 
10
LENS CONTROL PORT 
 
PIN  FUNCTION 
IRIS + 
IRIS - 
FOCUS + 
FOCUS - 
ZOOM + 
ZOOM - 
AUTO IRIS SIGNAL 
GROUND 
LENS CONTROL PORT AS SEEN FROM BACK OF 
CAMERA 
 
 
 
This  connector  provides  the  signals  necessary  to  control  the  iris,  focus,  and  zoom  of  most 
commercially available TV Zoom lenses.  The camera can be configured to operate lenses with 
unipolar  voltage  requirements  of  6V  up  to  12V  or  lenses  which  operate  with  bipolar  voltages 
from  ±6V  up  to  ±12V.    This  voltage  level  can  be  controlled  through  software.    The  default 
voltage will be set to 6V. The current capacity for each axis is 50mA. 
 
CARE  MUST  BE  TAKEN  NOT  TO  EXCEED  THE  LENS  MANUFACTURERS 
VOLTAGE SPECIFICATION. 
 
This connector also provides the signals necessary to operate a video auto iris type of lens. 
The  lens  control  connector  is  a  Hirose  3260-8S3.    The  mating  cable  connector  is  Hirose  3240-
8P-C(50).  This  connector  can  be  purchased  from  AVT  Canada  Inc.  or  from 
http://www.digikey.com
See Addendum for more detail.