The appliance, when installed, must be electrically grounded in ac-
cordance with local codes or, in the absence of local codes, with the 
National Electrical Code, ANSI/NFPA 70 or Canadian Electrical 
Code, CSA C22.1, if an external electrical source is utilized. This 
appliance is equipped with a three-prong [grounding] plug for 
your protection against shock hazard and should be plugged 
directly into a properly grounded three-prong receptacle. Do 
not cut or remove the grounding prong from this plug. For an 
ungrounded receptacle, an adapter, which has two prongs and a 
wire for grounding, can be purchased, plugged into the ungrounded 
receptacle and its wire connected to the receptacle mounting screw. 
With this wire completing the ground, the appliance cord plug can 
be plugged into the adapter and be electrically grounded. A
 7/8
" hole 
is provided in the junction box for use with a conduit connector if 
local codes require this type of protection.
Thermostat Installation
The thermostat should be installed in the same room as the furnace 
4' to 5' above the floor and away from another heat source (cooking 
stove, hot water heater, etc.) including walls and doorways with 
a heat source in an adjoining room. Do Not Install Thermostat 
on Outside Wall.
CAUTION: Label all wires prior to disconnection when servic-
ing controls. Wiring errors can cause improper and dangerous 
operation. Verify proper operation after servicing.
WIRING