Replacing Fan and Oiling the Motor
The fan motor should be cleaned and oiled once each heating season. 
To reach the motor, withdraw the metal shroud surrounding the fan 
blade by removing the screws on each side. Oil holes are located 
on the top at each end of the motor. Use a few drops of #10 motor 
oil. To clean the motor, blow air through its ventilation openings 
with a vacuum cleaner or low pressure air source.
If fan motor is replaced, the silicone rubber gaskets, see Page 16, 
Index No. 4, Part No. 712059, should also be replaced. The gaskets 
must be stretched to fit the motor bolts into the gasket holes and then 
the motor and gaskets installed on the motor mounting bars.
GENERAL  :  All  furnaces  have  been  fire-tested  to  check  for 
proper operation. This includes, main burner flame, pilot flame, fan 
operation, fan control, limit control and automatic valve operation. 
If the furnace fails to function on initial installation, it is advisable 
to re-check the following: 
1.  115 volts to the junction box.
2.  Inlet gas pressure.
3.  The 24 volt system.
4.  Type of gas being used and that shown on the rating label.
The Service Department at Empire Comfort Systems, Inc. may 
be  contacted  to  assist  in  servicing  furnace  or  call  a  qualified 
serviceman..
Servicing  the  Pilot  and  Main  Burners,  Pilot  Orifice, 
Thermocouple, and Main Burner Orifices: Disconnect the gas 
supply at the inlet to the control valve. Then remove the burner 
door to which the above components are attached.
Servicing The  Fan  Motor:  The  upper  front  panel,  the  shroud 
surrounding the fan blade and fan blade must be removed. See 
"Replacing Fan and Oiling the Motor" paragraph above.
Spark Igniter Does Not Light Pilot: With air in the gas line, such 
as when the furnace is first installed or was off all summer, the 
pilot flame may be too lean to ignite on the first few trials. Turn the 
control valve knob to pilot position and depress the red reset button. 
Holding the button down continually to bleed the line:
1.  Use lighter rod to light pilot with a match. 
2.  Use the piezo ignitor at 30 second intervals until it lights.
If Electrode Does Not Produce Spark:
1.  Check wire connections.
2.  Check gap for pilot burner to the electrode tip. Should be 
between 1/8" and 3/16". Electrode wire and tip must be more 
than 1/4" away from all other metal components.
If Pilot Does Not Light By Any Means:
1.  Check valve knob for being in the "Pilot" position.
2.  Check pilot adjustment for being full open (counterclockwise 
to open).
3.  If gas is available in the supply tubing, the pilot orifice and/or 
pilot burner is probably restricted by a spider web. Clean 
pilot assembly and relight.
If Pilot Does Not Remain On After Releasing Knob: 
1.  Follow  instructions  and  hold  button  down  longer  and 
harder.
2.  Determine if pilot flame extends past thermocouple; if not, 
adjust input or clean pilot burner.
3.  Replace  thermocouple  if  millivolts  read  less  than  15 
millivolts. 
Pilot Outage During Normal Operation:
1.  Check air inlet tube for a good tight fit at both ends (6" 
diameter tube).
2.  Check burner door and pilot hole cover for tight seal.
3.  Check input by manifold pressure gauge or gas meter.
Main Gas Valve Does Not Open When Thermostat Is Turned 
To On:
1.  Check  for  24  volts  to  valve  by  removing  one  wire  and 
touching to the SAME TERMINAL it was on. Terminal 
should  have a  light spark.  DO  NOT  SHORT ACROSS 
TERMINALS, AS IT WILL BURN OUT THE WALL 
THERMOSTAT.
2.  Thermostat wires at the wall may be shorted, so check for 
a faulty thermostat.
3.  To check for line voltage to furnace, remove lower front 
panel and switch compartment cover and short across two-
terminal fan control to allow fan to operate. (Figure 14)
SERVICE & MAINTENANCE SUGGESTIONS