Locating Wall Opening
The furnace is to be located on an outside wall. Locate wall studs so 
that wall opening will be located between wall studs. The furnace 
is 16 inches in width and normal 16 inches on center studs will 
not allow the furnace to be recessed into the wall unless a stud is 
repositioned. The wall opening required as shown in Figure 5 is a 
diameter of 7 1/2 inches.
A template is provided in furnace carton for positioning furnace 
on the wall. Also, refer to Figure 5 for positioning the furnace on 
wall and for locating gas line connection.
Installing Optional Side Outlets
Side outlet register, SOR-1 may be installed on one or both sides 
of the furnace at the required clearances of 18 inches to adjacent 
wall or combustible material as shown in Figure 4. 
  1.  Locate and cut the 5 1/2" square opening in the cabinet side 
using the template from the kit, exposing the inner liner 
knock-out.
  2.  Remove the knock-out. 
  3.  Place the register on the 5 1/2" opening with the louvers set 
for the desired direction and mark the mounting holes using 
the register as a template. 
  4.  Drill two (2) 1/8" diameter holes in cabinet side and fasten 
the register in place with two (2) 10 x 1" screws provided. 
Side outlet kit, 10" boot assembly with register, SOK-1 for warm 
air discharge into an adjoining room may be installed on either side 
of the furnace at the required clearance of 4 inches to adjacent wall 
as shown in Figure 7. 
  1.  Locate and cut the 5 1/2" square opening in the cabinet side 
using the template from the kit, exposing the inner liner 
knock-out.
  2.  Remove the knock-out. 
  3.  Using the inner and outer boots as hole templates, mark 
and drill eight (8) 1/8" diameter holes in the inner liner and 
cabinet side.
  4.  Using Figure 7 locate and cut a 6 3/4" square opening through 
walls. 
  5.  Prepare wall opening for the vent-air intake system (see 
Locating Wall Opening). 
  6.  With furnace in place, after checking alignment of side outlet 
opening in wall and furnace, place the 9 3/8" x 9 3/8" side 
outlet wall plate over outer boot, pass the outer boot through 
the wall and attach side outlet wall plate to furnace side of 
wall with two (2) 10 x 1" screws provided. 
  7.  Fasten outer boot to the cabinet side with four (4) 8 x 1/4" 
screws provided. 
  8.  Position and attach inner boot to inner liner with four (4) 8 
x 1/4" screws provided. 
  9.  Locate the register with its louvers positioned for the desired 
air discharge direction and mark the mounting holes using 
the register as a template. 
  10.  Drill two (2) 1/8" diameter holes in the wall and fasten the 
register in place with two (2) 10 x 1" screws provided.
Figure 5
                       Figure 6                      Figure 7
INSTALLATION INSTRUCTIONS