Gas Fireplace Insert
10002964
Fan Kit Installation
115 Volt, 60 Hz. 56W
The fan kit  includes the following:  fan, temperature 
sensor, speed control and a 6 ft. cord. The following 
explains how to start and set the fan for automatic 
operation.
1.  Plug in the electrical cord.
2.  Start gas fire - see lighting procedures.
3.  Turn on fan speed control.
4.  Wait until the unit has warmed up sufficiently to 
activate the temperature sensor.
5.  Once fan starts, adjust speed control to desired fan 
speed. The fan will now automatically come on every 
time the fireplace is in operation. Should the fan not 
be needed simply turn off the speed control.
The appliance, when installed must be 
electrically connected and grounded in 
accordance with local codes or, in the ab-
sence of local codes, with the current CSA 
C22.1 Canadian Electrical Code.
For U.S.A. installations, follow local codes 
and the national electrical code, ANSI/
NFPA No. 70.
Should this fan require servicing, the 
power supply must be disconnected. For 
rewiring  of any replacement components 
refer to Figures 13 & 14.
FP1252
FK24 install
1/03
Fan is installed 
at the back of 
the air intake 
box
Stud
Fan Speed Control/Junction Box
Valve
Thermal Sensor is 
attached to burner 
base
FP1252
Fig. 13  Fan location.
Stud
FP394
WIRING DIAGRAM
11/20/96
FP394
Black
White
Ground
Speed 
Control
Temperature Sensor
Fan
Fig. 14  Wiring diagram RN/RP.
Fan Removal Instructions
1.  Turn off gas and electricity.
2.  Remove the  front glass.
3.  Remove the logs.
4.  Remove burner assembly and rear log support plate.
5.  Remove the fan mounting nuts (2). (Fig. 13)
6.  Slip off the electrical connector at the motor.
7.  Lift out the fan.
8.  To reinstall, reverse procedure.