Gas Fireplace Insert
10002964
������
������������
�����
Leveling Bar
Set Screws
FP1658
Fig. 8  Adjust leveling bar on A132 only.
2' Min.
2'
(610mm)
Min.
3'
Min.
0 To 10'
3' 
(914mm)
Min.
0 To 10'
AC246
4/1/96
Reference
Point
(3m)
Fig. 9  Example of the 2', 3', 10' rule.
AC246a
Venting and Installation
Installer must attach red warning label to 
fireplace.
WARNING
This fireplace has been converted for use with 
gas only and cannot be used for burning wood 
or solid fuels unless all original parts have been 
replaced and the fireplace has been re-approved 
by the authority having jurisdiction.
Cutting any sheet metal parts of the fire-
place, in which the gas fireplace insert is 
to be installed, is prohibited.
Ensure there are no obstructions to side 
air passages of decorative trim once in-
stalled on insert.
WARNING
Some factory built fireplaces have air passages 
on face of fireplace for zero clearance capabili-
ties. All trim kits are designed so as to allow air-
flow to these passages. Under no circumstances 
should these passages be blocked.
Venting Instructions
Canadian Installations: 
The venting system must be installed in accordance 
with the current CSA-B149.1 installation code, and the 
authority having jurisdiction.
U.S.A. Installations: 
The venting system must be installed in accordance 
with the current National Fuel Gas Code, ANSI Z223.1/
NFPA 54.
Minimum clearances to combustible materials is 1" (25 
mm) for B Vent (use of single wall vent is not al-
lowed).
As with any natural draft appliances, the vent cap must 
always extend a minimum of 2' (610 mm) above any 
structure within a 10' (3 m) horizontal plane. (Fig. 9)
A minimum 12’ (3.7 m) vent height is re-
quired to effectively vent this fireplace.
1.  Gas inserts are designed for recessed 
installations into solid fuel masonry or factory built 
noncombustible fireplaces that have been installed 
in accordance with the National, Provincial, State 
and local building codes.
2.  Measure for minimum fireplace opening requirement 
on Page 4 of this installation manual.  (If firebrick 
[refractory] is removed from a factory built 
fireplace in order to gain minimum gas fireplace 
insert opening requirements, a minimum of 1/4" 
(6 mm) air space is required between the gas 
insert fireplace's outer casing and the inner wall 
of the factory built fireplace).
3.  To assure top performance, safety and efficiency, 
all inserts must be installed with an approved 4" 
diameter flue liner, with exception of A125, which 
should be installed with an approved 3" liner,as per 
CSA-B.149 or National Fuel Code ANSI Z223/NFPA 
54. 
4.  Flue damper must be fully blocked in the open 
position or removed for installation.
5.  The chimney must be clean and in good working 
order and constructed of noncombustible materials.
6.  Make sure that all chimney cleanouts fit properly so 
air cannot leak into the chimney.
7.  Glass door, screen kits and log grate may be 
removed for installation of insert into factory built 
fireplace.
8.  Install the insert without the trim frame and make all 
gas, venting and electrical connections.
9.  Install decorative trim frame. Please refer to Frame 
Assembly and Mounting instructions In this manual.