INTRODUCTION  
 
Your new MODEL 94NC is a non-catalytic unit designed to meet the most stringent emissions 
standards without  use of a catalytic combustor.  This effect is achieved through  use of 
secondary air which is mixed with primary air in  unit’s firebox. 
  
For peak performance, we suggest the use of natural seasoned hard wood, loading wood 
length way from front to rear.
  
 
NOTE: Soft woods such as pine, create more creosote, clogging of chimney and produce a less 
efficient burn performance. 
 
You should not burn trash or garbage, artificial or paper logs, gift wrapping, treated or 
painted wood or any type of coal or flammable fluids. 
 
The primary air, which is controlled by  user, burns the wood.  Secondary air is admitted into 
firebox through  secondary air tubes at  top of the firebox.  This secondary air burns  impurities 
in  smoke released from  initial wood burning.  The temperature necessary for this combustion 
is maintained through  firebrick refractory.  If any more technical information is necessary, 
contact your local dealer.  
 
 
Under specific test conditions this heater has been shown to deliver heat at rates ranging from 
approximately : 
   11,900 BTU/HR. on Low 
   42,100 BTU/HR. on High 
 
 
This unit is equipped with a standard room air blower. 
 
 
 
CAUTION
 
YOUR CHIMNEY OR FLUE MUST BE CORRECTLY SIZED. A CHIMNEY OR FLUE 
THAT IS TOO SMALL OR LARGE IN DIAMETER OR TOO SHORT, CAN CAUSE 
YOUR STOVE TO SPILL SMOKE WHEN THE DOOR IS OPENED. 
 
 
 
Page 3