SECTION II 
 
MASONRY INSERT INSTALLATION 
 
The Model 94NC may be installed using an all masonry  fireplace  built  in accordance with 
Uniform  Building  Code  and National  Fire Protection Association (NFPA).  The first step  in  
this  type of installation is to determine   acceptability  of    fireplace  and chimney for use with 
a woodstove.   Both    construction and condition of  fireplace are important consid-
erations  when  installing a woodstove. The chimney should extend at  least 3'  above  roof and 
at least 2' above any point of    roof  within 10'. 
 
 
 
 
 
 
 
MINIMUM CLEARANCE MASONRY INSERT
 
 
 
A.  Side Wall Combustible 
B.  Front Floor Protector 
C.  Side Floor Protector 
D.  Side Wood Trim 
E.  Top Wood Trim 
F.  Mantel or Brackets 
 
 
12" 
16" 
  8" 
10" 
18" 
24" 
MODEL 94NC
 
 
1.  The hearth must be of masonry construction and  must extend a  minimum of 16" in front of 
firebox opening and  a  minimum of 8" to either side of firebox opening. 
Minimum floor protection under unit must have an R-value of 0.30. 
2.  If there is not minimum hearth protection from  front of   firebox opening and front of  
masonry hearth, a  floor protector must be used in front of  hearth  to  protect  combustible 
materials.  The floor protector must be 3/8" minimum thickness non-combustible material 
or equivalent.(See Page 12,13). 
F
B
A
E
C
D
 
CAUTION
 
REMEMBER  TO HAVE YOUR CHIMNEY INSPECTED FOR  LEAKS AND  BLOCKAGE 
BEFORE YOU INSTALL YOUR STOVE. “DO NOT CONNECT THIS UNIT TO A 
CHIMNEY FLUE SERVING ANOTHER APPLIANCE.” 
 
 
 
Page 5