F37 Regency
®
 Rear Flued Room Sealed Freestanding Gas Heater
INSTALLATION
Diagram 2
HORIZONTAL INSTALLATIONS
Diagram 1
*Diagram 2:  Local codes or regulations may 
require different clearances.
RESIDENTIAL AND MANUFACTURED HOMES / 
MOBILE HOMES INSTALLATIONS
You will require the following components with your new Regency
®
 Rear Flued Room Sealed Freestanding Gas Stove. Please review your product 
to make sure you have everything you need. In the event that you are missing any part, contact your dealer. 
Note:  These are the minimum pieces required. 
 
 
Other parts may be required for your particular installation. 
Minimum components for a Horizontal Installation: 
946-112 
Horizontal Termination Kit which includes:
 
6-5/8" dia. x 18" (168mm dia. x 457mm) Black Pipe 
 
4" dia. x 18" (102mm dia. x 457mm) Aluminum Flue
 
Astro Riser Vent Terminal
 
Wall Penetration Heat Shield for Heat Sensitive walls
  
(Wall 
Thimble) 
(2 
pcs)
 1 
Decorative 
Wall 
Trim 
(Black)
 1 
Tube 
Mill-Pac
  
Screws
Optional Components:
946-204  45
o
 Elbow - 6-5/8" (168mm) Black pipe 
  
and 
4" 
(102mm) 
Aluminum 
Flue
946-205 
 
Vinyl Siding Shield for Riser Vent
  
Terminal
946-208/P  
Flue 
Guard
940  
Square 
Wall 
Thimble 
Cover*
942  
Wall 
Penetration
  
Heat 
Shield*
* Simpson Dura-Vent  components
 
1)  Set the unit in its desired location. Check to 
determine if wall studs are in the way when 
the fl ueing system is attached. If this is the 
case, you may want to adjust the location 
of the unit.
2)  Assemble the desired combination of pipe 
and elbow to the appliance adapter with pipe 
seams oriented down. Offset the pipe seams 
as double seams in one place will cause the 
outer pipe to take an oval shape. Kit comes 
complete with 18" (457mm) of straight fl ue 
- 6-5/8" (168mm) dia. black outer pipe and 
4" (102mm) dia. inner fl ue. 
3)  With the pipe attached to the stove, slide 
the stove into its correct location, and mark 
the wall for a  
9-1/2" (241mm) (inside 
dimensions) round hole. The center of the 
round hole should line up with the centerline 
of the horizontal pipe, as shown in diagram 
1. Cut and frame the 9-1/2 (241mm) round 
hole in the exterior wall where the fl ue will 
be terminated. If the wall being penetrated is 
constructed of non-combustible material, i.e. 
masonry block or concrete, a  7" (178mm) 
diameter hole is acceptable.
 
Note:
 a)  The horizontal run of fl ue should have 
a 1/4 inch (6mm) rise for every 1 foot 
(305mm) of run towards the termination. 
Never allow the fl ue to run downward. 
This could cause high temperatures and 
may present the possibility of a fi re.
 b)  The location of the horizontal fl ue ter-
mination on an exterior wall must meet 
all local and national building codes, 
and must not be blocked or obstructed. 
See the diagram in the "External  Flue 
Termination Locations" section.
 c)  Snorkel Terminations:
 
 
For installations requiring a vertical rise 
on the exterior of the building, Astro Riser 
Vent Terminations as shown in Dia. 2 
is available. Follow the same installa-
tion procedures as used for standard 
Horizontal Termination. 
 
 
NEVER install the Astro Riser vent upside 
down.