INSTALLATION
FLUEING ARRANGEMENTS - VERTICAL TERMINATIONS 
for both Residential & Manufactured Homes/Mobile Homes
Offset to Vertical Terminations
If  connecting to a  Dura-Vent system,  
the Adapter to Dura-Vent # 640-994 
is required.
Vertical Terminations 
with Co-linear Flex System
The shaded  area in the diagram  shows the allowable  vertical 
terminations installed in a masonry chimney.
 All vertical  fl ue instal-
lations require the Flue Restrictor to be set to 32mm open. All Vertical 
Flue Terminals must be Simpson Dura Vent (Abey Australia) DV 980 
MAS (Australian Modifi ed.)
Vertical Terminations 
using Dura-Vent Flueing System
The shaded areas in the two diagrams below show all allowable com-
binations of straight vertical and offset to vertical runs with vertical 
terminations.
 Maximum  one 90
o
 elbow.  All vertical and offset to vertical 
fl ue installations require Flue Restrictor to be set to  32mm  open. If the fl ue 
is ENCLOSED in a chase (min. size 229mm x 229mm) maintain a  32mm 
clearance to combustibles. All Vertical Flue Terminals must be Simpson 
Dura Vent (Abey Australia) DV 980 MAS (Australian Modifi ed.)
Straight Vertical Terminations
Flue Restrictor Position
Vent Restrictor
Vent
Restrictor
Plate
Vent Restrictor
(fully open)
Vent
Restrictor
Plate
44.5mm
44.5mm
32mm
32mm
To set the Flue restriction 
as indicated in the diagram, 
simply loosen the screws 
and push the fl ue restrictor 
plate to the correct position. 
Tighten the screws.
216mm
9.1m
Max.
3.2m
Min.
1
1
1
2
4
5
6
7
8
2
1
3
9
Horizontal Distance (meters)
V
ertical
Height
(meters)