AGM300 - Current Loop Interfaces 
Optional 4–20 mAdc Outputs 
Upon installation of the optional 4–20 mAdc Interface Board (Page 7) (P/N 3015-3133), the AGM300 has the 
capability of providing dual 4-20 mAdc scrolling current loop outputs for connection to external monitoring 
devices. 
The interfaces are set up as follows: 
Loop 1 indicates zone area 
Loop 2 indicates PPM 
Connection 
The external devices are connected to the AGM300 using a shielded dual twisted pair cable. Use any of the 
remaining service knockouts to gain access to the interior of the monitor. Locate the Dual 4–20 mAdc Output 
connector (Page 7) and remove it from the circuit board.  Secure the wire leads to the connector orienting them 
as shown in the diagram below. Check to make sure the polarity matches the wiring at the external device. 
When you are through securing the connections, carefully plug the connector back onto the circuit board. 
NOTE: When one or both current loop outputs are not used, install a jumper wire between the ground the 
unused loop terminal(s) to prevent the system from generating a current loop fault. 
 
CAUTION - The loop outputs have isolated grounds.  
Therefore, the cable shield should be terminated at the 
receiver and not at the AGM300.  The signal for both 
current loops must be returned to the AGM300. 
 
Current Loop Connector 
 
 
 
 
 
 
NOTE: The ground connections are common. 
 
LOOP 1 = ZONE  
LOOP 2 = PPM 
5 mAdc = Zone 1 
Default 
 
6 mAdc – Zone 2 
0.016 mAdc = 1 PPM 
 
--- 
Scalable via Software 
 
--- 
4 mAdc   = 0 PPM 
 
20 mAdc = Zone 16 
20 mAdc = 1000 PPM 
 
 
 
 
LOOP 2 
PPM 
LOOP 1 
ZONE 
NOTE: 
SIGNAL OUT 
ONLY DO NOT 
APPLY POWER 
GROUND