Wayne T100S10-2 Manual De Usuario

Descargar
Página de 28
2
Operating Instructions and Parts Manual  
Deep Well Submersible Pump
www.waynepumps.com
General Safety 
Information
 (Continued) 
nOTe: See Installation Wiring Diagrams 
for typical wiring hookups and control 
box identification.
fuse Size
HP
Volts Standard Dual elem.
1/2
230
20
10
3/4
230
25
5
1
230
30
20
Table 1 - recommended fusing data 
for 60 Hz, single phase, 3-WIre 
submersible pump/motor 
fuse Size
HP
Volts Standard Dual elem.
1/2
230
20
10
3/4
230
25
5
1
230
30
20
Table 2 - recommended fusing data 
for 60 Hz, single phase, 2-WIre 
submersible pump/motor
WIrInG InSTallaTIOn
Single Phase, 3 Wire
 
hazardous voltage! The 
electrical system in this pump 
CAN cause electrical shock 
and death. Permanently ground control 
box, metal plumbing, and motor frame 
in accordance with national and local 
codes. use copper grounding wire with 
a diameter no less than wires carrying 
current to motor.
1.  at well head, connect grounding 
wire to grounding terminal. 
Grounding system must meet 
all applicable national and 
local electrical codes. For more 
information, contact local code 
officials.
2.  Permanently close all unused 
openings in this and other 
equipment.  Disconnect power 
before working on or around control 
box, pipes, cable, pump, or motor.
3.  Install control box vertically on wall 
with top side up.
nOTe: three-wire pumps have three 
power supply wires (Red/Black/yellow) 
and one ground wire (Green). When 
operated without a control box, three-
wire pumps will not operate properly 
and will likely cause motor to burn out.
12. Use wire of adequate size to 
minimize voltage drop at the motor.
13. Pipe joint compound can cause 
cracking in plastics. Use only 
plumbers seal tape when sealing 
threaded joints in plastic pipe 
or when connecting pipe to 
thermoplastic pumps.
 
do NoT handle 
  pump or pump 
motor with wet hands, when standing 
on a wet or damp surface or when 
standing in water.  Fatal electrical shock 
Could occur!
 
Pump motor is 
  equipped with an 
automatic resetting thermal protector 
and MAY restart unexpectedly. Protector 
tripping is an indication of motor 
overloading because of operating 
pump at low heads (low discharge 
restriction), excessively high or low 
voltage, inadequate wiring, incorrect 
motor connections, inadequate cooling 
or defective motor or pump. 
Pre-Installation
1.   Inspect pump and motor for delivery 
damage. 
2.   Before installing pump, remove 
all fine sand particles and foreign 
matter. See Initial Startup section (on 
page 4) for more information.
3.   Install pump at least 15-20 feet 
below the lowest water level 
reached with pump running (lowest 
drawn-down water level), and at 
least 5 feet above bottom of well.
to maximize performance, pump should 
process only cold water that is clear and 
free of entrained air.
Warranty is void if (1) system pumps 
excessive sand resulting in early 
pump wear, (2) water is corrosive, (3) 
entrained gas or air causes reduced flow 
and cavitation, or (4) pump operates 
with discharge valve closed, resulting in 
serious damage.
electrical System
WIrInG/GrOUnDInG
hazardous voltage! The 
electrical system in this 
pump can cause electrical 
shock and death. Permanently ground 
pump, motor and control box before 
connecting to electrical supply. Ground 
pump and motor in accordance with all 
codes and ordinances that apply. use 
copper grounding wire with a diameter 
no less than wires carrying current to 
motor.
1.  Permanently ground pump, motor 
and control box before connecting 
power cable to power supply. 
Connect ground wire to approved 
ground first, and then connect to 
equipment being installed.
2.  Motor is supplied with copper 
grounding wire. Splice wire to 
copper conductor that matches wire 
size shown in table 3, on page 3. See 
Wire Splicing under Installation, on 
page 4.
 
do NoT ground to 
gas supply line. 
Fire, explosion, 
and death or serious injury Could 
result. 
 
Fire and electrical 
shock hazard! If 
using a power 
supply wire larger than No. 10 (5 mm
2
between pump and control box, run 
wire to separate junction box. Connect 
junction box to control box with a No. 
10 (5 mm
2
) wire.
For more information, contact your 
local code officials.
WIrInG COnneCTIOnS
all wiring must meet national electrical 
Code requirements, as well as local code 
requirements.
Use only copper wiring for connections 
to pump and control box.
to prevent wire overheating and 
excessive voltage drop at motor, use 
wire size at least as large as size shown 
in table 3 on page 3 (based on HP and 
length of wire run).