Wayne T100S10-2 Manual De Usuario

Descargar
Página de 28
3
www.waynepumps.com
electrical System
 
(Continued) 
 
use only control  
  box specified 
for your pump. Make sure motor and 
control box match (see Table 4, on page 
3). Failure to do so WIll void warranty.
4.  Install circuit protection and 
component protection in compliance 
national electrical Code, Part 1. 
Consult with appropriate code 
officials for more information on 
how to do this.
If main overload trips, look for the 
following:
1. Shorted capacitor
2. Voltage problems
3. overloaded or locked pump.
Single Phase, 2 Wire
two-wire pumps have two power supply 
wires and one ground wire (Green). a 
control box is not required. See Figure 
1b for correct hookup for 230 volt 
2-wire motors only.
Operating Instructions and Parts Manual  
Deep Well Submersible Pump
Cable Size
Volts
HP
14 
(2 mm
2
)
12 
(3 mm
2
)
10 
(5 mm
2
)
(7 mm
2
)
(13 mm
2
)
(21 mm
2
)
(25 mm
2
)
(34 mm
2
)
(41 mm
2
)
(50 mm
2
)
1/2
400 
(121.9)
650 
(198.1)
1020 
(310.9)
1610 
(490.7)
2510 
(765)
3880 
(1182.6)
4810 
(1466.1)
5880 
(1792.2)
7170 
(2185.4)
8720 
(2657.9)
230
3/4
300 
(91.4)
480 
(146.3)
760 
(231.6)
1200 
(365.8)
1870 
(570)
2890 
(880.9)
3580 
(1091.2)
4370 
(1332)
5330 
(1624.6)
6470 
(1972.1)
1
250 
(76.2)
400 
(121.9)
630 
(192)
990 
(301.8)
1540 
(469.4)
2380 
(725.4)
2960 
(902.2)
3610 
(1100.3)
4410 
(1344.2)
5360 
(1633.7)
nOTe: Specified maximum wire lengths are valid with motor voltage greater than or equal to 95% of service entrance 
voltage and motor running at maximum nameplate amperes. If service entrance voltage is at least motor nameplate voltage 
under normal load conditions, 50% additional length is permissible for all sizes shown.
Table 3 - Power supply wire (cable) length in feet (m) 
1 phase, 2 or 3 wire cable, 60 Hz (copper wire size—service to motor)
HP
Voltage
Wires
Pump Model 
no.
Control Box 
no.
1/2
230
3
t50S10-2
16965-002
1/2
230
2
t50S10-2
none
1/2
115
2
t51S10-4
none
3/4
230
3
t75S10-2
16966-002
3/4
230
2
t75S10-4
none
1
230
3
t100S10-2
16967-002
Table 4 - Control box chart
L1 M1
M2
L2
CONTROL
BOX
L1L2R Y B
FUSED 
DISCONNECT
SWITCH
115V or
230V LINE
GROUND
RED
YELLOW
BLACK
PRESSURE
SWITCH
WELL
CASING
GROUND
L1 M1
M2
L2
FUSED
DISCONNECT
SWITCH
TO LINE
GROUND
RED
BLACK
PRESSURE
SWITCH
WELL
CASING
GROUND
(GREEN)
Follow color coding when 
connecting control box wires. 
(Yellow = Y, Red = R, Black = B)
figure 1a - 3 wire, 1/2-1HP quick 
disconnect box
figure 1b - Single phase, 2 wire 
connections