Guardian Technologies 004582-2 Manual De Usuario

Descargar
Página de 36
6
Section 2 – Operation
Commercial-Industrial-Residential Portable Generator System
2.1 KNOW 
THE 
GENERATOR
Read the Owner’s Manual and Safety Rules before operating this 
generator.
Compare the generator to Figures 4 through 6 to become familiarized 
with the locations of various controls and adjustments. Save this 
manual for future reference.
Figure 4 - Control Panel
1.  12 Volt DC, 10 Amp Receptacle – This receptacle allows the 
capability to recharge a 12 volt DC storage battery with provided 
battery charge cables.
2.  120 Volt AC, 20 Amp, Duplex Receptacle – Supplies electrical 
power for the operation of 120 Volt AC, 20 Amp, single-phase, 60 
Hz electrical lighting, appliance, tool and motor loads.
3.  120 Volt AC, 20A Duplex GFCI Receptacle – Supplies ground 
fault protected electrical power for operation of 120 volt AC 20 
amp, single-phase, 60 Hz electric lighting, appliances, tools and 
motor loads.
4.  120 Volt AC, 30 Amp Locking Receptacle – Supplies electrical 
power for the operation of 120 Volt AC, 30 Amp, single-phase, 60 
Hz electrical lighting, appliance, tool and motor loads.
5.  120/240 Volt AC, 30 Amp Locking Receptacle – Supplies 
electrical power for the operation of 120 and/or 240 Volt AC, 30 
Amp, single-phase, 60 Hz, electrical lighting, appliance, tool and 
motor loads.
6.  120/240 Volt AC, 50 Amp Receptacle (Located on underside 
of control panel)– Supplies electrical power for the operation of 
120/240 Volt AC, 50 Amp, single-phase, 60 Hz, welder or motor 
loads.
7. Air 
Cleaner – Filters intake air as it is drawn into the engine.
8. Choke 
Knob – Used when starting a cold engine.
9. Winter/Summer 
Valve – See “Cold Weather Operation/De-icer” 
section.
Figure 5 - Generator Controls
10. Circuit Breakers (AC) – Each receptacle is provided with a 
push-to-reset circuit breaker to protect the generator against 
electrical overload. (50 amp uses toggle reset)
11. Fuel Tank – Tank holds 16 U.S. gallons of fuel.
12. Grounding Lug – Ground the generator to an approved earth 
ground here. See "Grounding the Generator" for details.
13.  Idle Control Switch – The idle control runs the engine at normal 
(high) speeds when there is an electrical load present and runs 
the engine at idle (low) speeds when a load is not present.
14. Start/Run/Stop  Switch – Controls the operation of the 
generator.
15. Oil Fill – Use this point to add oil to engine.
16.  Fuse - 10 Amp (Located at rear of control panel) – Protects 
the DC control circuit from overload. If this fuse element has 
melted open the engine will not be able to crank and start.
Figure 6 - Engine Control Panel
14
8
9
7
15
12
11